Set Mode Details
Set Item 1 [SQUELCH]
hotkey funct-0
Function: Set the Squelch threshold level for the AM and FM-Narrow
modes.
Available Values: 0 ~ 15
Default: 01
Set Item 2 [WFM SQL]
Function: Set the Squelch threshold level for the FM-Wide
mode.
Available Values: 0-15
Default: 02
Set Item 3 [NAME SET]
Function: Store Alpha-Numeric "Tags" for the Memory
channels.
Name Storing:
© Recall the memory channel to be named.
0 Recall Menu Item 3, then press the [BAND(SET)AR] key momentarily.
(D Turn the DIAL to select the desired first letter, number,
or symbol, then press the
[BAND(SET)AR] key momentarily to save the first letter/number/
symbol.
@ Repeat the previous step as necessary to complete, pressing
the [BAND(SET)AR]
key after each entry.
(D Press the PTT key momentarily to save the your new setting
and exit to normal operation.
VX-5R operating manual
61
Set Mode
Set Item 4 [ICON]
Function: ICON selection.
© Recall Menu Item 3. then press the [BAND(SET)AR] key
momentarily.
(2) Turn the DIAL to select the desired band or mode on which
you wish to utilize an
Icon, then press the [BAND(SET)AR] key momentarily.
(D Turn the DIAL to select the desired Icon to be displayed
in place of the regular indicator.
@ Press the PIT key momentarily to save the your new setting
and exit to normal operation.
Set Item 5 [VFO]
Function: Select or disable the VFO Band edge for the current
band.
Available Values: ALL/BAND
Default: BAND
ALL: When the VFO frequency reaches the high edge of the
current band, the VFO
frequency will jump to the low band edge of the next band
(or vice versa).
BAND: When the VFO frequency reaches the high band edge of
the current band, the
VFO frequency will jump to the low band edge of the current
band (or vice versa).
Set Item 6 [ARS]
Function: Enable/disable the Automatic Repeater Shift function.
Available Values: ON/OFF
Default: ON
Set Item 7 [RPT SHIFT] Function: Set the Repeater Shift Direction
Available Values: -RPT/+RPT/SIMP Default: Depends on the transceiver
version.
Set Item 8 [SHIFT]
Function: Set the magnitude of the Repeater Shift.
Available Values: 0.00 ~ 99.95 MHz
Default: Depends on the transceiver version, as well as the
setting of Menu #06 (ARS).
Set Item 9 [VFO SPLIT]
Function: Enable/disable "VFO Split" Operation
Available Values: ON/OFF
Default: OFF
When this feature "ON," you can operate in a "split"
mode between the Main and Sub
VFO frequencies (the Main VFO will be used for Rx, while the
Sub VFO will be used for
Tx).
62
VX-5R operating manual
set woae
Set Item 10 [VFD LINK]
Function: Enable/disable the VFO Link feature.
Available Values: ON/OFF
Default: OFF
When this feature "ON," the Main and Sub VFOs are
"slaved" so that they change frequency
together.
Set Item 11 [VFD STEP] Function: Setting of the synthesizer
steps. Available Values: 5/9/10/12.5/15/20/25/50/100 kHz Default:
Depends on the transceiver version.
Set Item 12 [RESUME]
Function: Select the Scan Resume mode.
Available Values: 5 SEC/BUSY/HOLD
Default: 5 SEC
5 SEC: The scanner will hold for 5 seconds, then resume whether
or not the other station
is still transmitting.
BUSY: The scanner will hold until the signal disappears,
then will resume when the carrier
drops.
HOLD: The scanner will stop when a signal is received, and
will not restart.
Set Item 13 [SCAN LAMP]
Function: Enable/disable the Scan lamp while paused.
Available Values: ON/OFF
Default: ON
Set Item 14 [RXSAVE]
Function: Select the Receive-mode Battery Saver interval
("sleep" ratio). Available Values: OFF/200mS(l:l)/300mS(l:1.5)/500mS(1:2.5)/ls(l:5)/2s(l:
10)
Default: 200mS( 1:1)
Set Item 15 [TXSAVE]
Function: Enable/disable The Transmit Battery Saver.
Available Values: ON/OFF
Default: OFF
Set Item 16 [APD]
Function: Set the Automatic Power-Off time.
Available Values: OFF/30 min/l hour/3 hours/5 hours/8 hours
Default: OFF
VX-5R operating manual 63
Set Mode
Set Item 17 [BUSY LED]
Function: Enable disable the BUSY LED while the Squelch is
open.
Available Values: ON OFF
Default: ON
Set Item 18 [ARTS BEEP]
Function: Select the Beep option during ARTS operation.
Available Values: IN RANGE ALWAYS OFF
Default: IN RANGE
INlRANGj;: Beeps sound only when the radio first detects
that you are within range.
ALWAYS.: Beeps sound every time a polling transmission is
received from the other
station (every 15 or 25 seconds when in range).
OFF: No alert beeps sound.
Set Item 19 [ARTS ITVL]
Function: Select the Polling Interval during ARTS operation.
Available Values: 15 SEC 25 SEC
Default: 25 SEC
This setting determines how often the other station will
be polled during ARTS operation,
Set Item 20 [KEY BEEP]
Function: Enable disable the Keypad beeper.
Available Values: ON OFF
Default: ON
Set Item 21 [EDGE BEEP]
Function: Enable disable the Band-edge beeper while scanning.
Available Values: ON OFF
Default: OFF
When this feature "ON." a beep will sound when
the scanner reaches the band edge (during
VFO Scanning) or when it reaches Memory channel "I"
(during Memory Channel
Scanning).
Set Item 22 [BELL]
Function: Select the CTCSS Bell ringer repetitions. Available
Values: OFF I 3 5 8 REPEAT Default: OFF
64
VX-5R operatic, mam m
bet Mode
Set Item 23 [MON^T-CAL]
Function: Select the MONI key (just below the PTT switch)
function.
Available Values: MON/T-CAL
Default: Depends on the transceiver version.
MON: Pressing the MONI key causes the noise tone Squelch
to be over-ridden, allowing
you to listen for weak (or non-encoded) signals. T-CAL: Pressing
the MONI key activates a 1750-Hz burst tone, used for repeater
access in
many countries.
Set Item 24 [HOME/REV]
Function: Select the function of the [HM/RV(EMG)] key. Available
Values: HOME/REV Default: Depends on the transceiver version.
HOME: Pressing this key instantly recalls a favorite "Home"
channel. REV: Pressing this key reverses the transmit and
receive frequencies during repeater
operation.
Set Item 25 [LAMP MODE] Function: Select the LCD/Keypad Lamp
mode. Available Values: KEY/TOGGLE/5 SEC Default. KEY
KEY: Illuminates the LCD/Keypad for 5 seconds when any key
is pressed.
TOGGLE: Pressing the LAMP key toggles LCD/Keypad lamp On/Off.
5 SEC: Pressing the LAMP key illuminates the LCD/Keypad for
5 seconds.
Set Item 26 [TOT]
Function: Set the TOT time.
Available Values: OFF/1 min/2.5 min/5 min/10 min
Default: 2.5 min
The time-out timer shuts off the transmitter after continuous
transmission of the programmed
time.
Set Item 27 [BCLO]
Function: Enable/disable the Busy Channel Lock-Out feature.
Available Values: ON/OFF
Default: OFF
Set Item 28 [CLOCK SFT]
Function: Shifting of CPU clock frequency.
Available Values: ON OFF
Default: OFF
This function is only used to move a spurious response "birdie"
should it fall on a desired
frequency.
VX-5R operating manual 65
Set Mode
Set Item 29 [SQL TYPE]
Function: Select the Tone Encoder and'or Decoder mode. Available
Values: OFF TONE TONE SQL DCS Default: OFF
TONE: CTCSS Encoder
TONE SQL: CTCSS Encoder Decoder
DCS: Digital Coded Squelch Encoder Decoder
Set Item 30 [TONE SET]
Function: Setting of the CTCSS Tone Frequency
Available Values: 39 standard CTCSS tones
Default: 100 Hz
. 1 / In this mode, press the [2(CD)TAG] key (not PTf) to
save the new setting
n^^V>_ and exit to normal operation.
Set Item 31 [DCS SET] Function: Setting of the DCS code. Available
Values: 104 standard DCS codes. Default: 023
!„ / /// this mode, press the [2(CD)TAG] key (not PTJ)
to save the new setting
\
>_ and exit to normal operation.
/
Set Item 32 [DTMF SET]
Function: Programming the DTMF Autodialer.
DTMF Autodialer Programming:
® After selecting Menu Item 32. press the [BAND(SET)AR]
key momentarily.
(2) Rotate the DIAL to select the autodial memory number
you want to store (9 memories
are available).
(D Press the [BAND(SET)AR] key momentarily, then key in the
phone number you want
to store (maximum: 16 digits).
@ If you make a mistake, press the MONI key twice to clear
the current digit and reenter
the correct number.
© After entering the final digit, press the PTT key momentarily
to save the new setting
and exit to normal operation.
66
VX-5R operati.\g mam-al
Set Mode
Set Item 33 [CW ID]
Function: Program and activate the CW Identifier (used during
ARTS operation).
CW IDer Programming:
© After selecting Menu Item 33, press the [BAND(SET)AR]
key momentarily.
(2) Turn the DIAL one click to change the display from OFF
to ON (CW IDer ON).
(D Press the [BAND(SET)AR] key momentarily, then turn the
DIAL to select the first
letter number of your callsign. and press the [BAND(SET)AR]
key momentarily to
save the first letter/number.
@ Repeat the previous step as necessary to complete your callsign.
pressing the
[BAND(SET)AR] key after each entry.
(D Press the PTT key momentarily to save the new setting and
exit to normal operation.
Set Item 34 [SPEC-ANAL]
Function: Select the Spectrum Analyzer (Spectra-Scope™)
Sweep mode. Available Values: SINGLE/CONTINUE Default: SINGEE
SINGLE: The transceiver sweeps the current band once."
CONTINUE: The transceiver sweeps the current band repeatedly
until the Spectrum Analyzer
(Spectra-Scope™) is turned off
Set Item 35 [SMRT SRCH]
Function: Select the Smart Search Sweep mode.
Available Values: SINGLE/CONTINUE
Default: SINGLE
SINGLE: The transceiver sweeps the current band once in each
direction starting on
the current frequency. All channels where activity is present
(up to 15 in
each direction) are loaded into the Smart Search memories.
Whether or not
all 3 1 memories are filled, the search stops after one sweep
in each direction.
CC)NJ1NJJ£: The transceiver makes a sweep in each direction
as with the "SINGEE"
mode, but if all 3 1 channels are not filled after the first
sweep, the radio
continues sweeping until they are all filled.
Set Item 36 [RX MODE]
Function: Select the Operating mode.
Available Values: AUTO/N-FM/AM W'-FM
Default: AUTO (Mode automatically changes according to operating
frequency)
Set Item 37 [LOCK MODE]
Function: Select the Control Locking lockout combination.
Available Values: KEY DIAL PTT KEY-DIAE KEY-PTT DIAE+PTT
ALL
Default: KEY
VX-5R operatic manual
67
bet ivioae
Set Item 38 [HALF DEV]
Function: Reducing the Deviation level by 50%.
Available Values: ON OFF
Default: OFF
Set Item 39 [LANGUAGE]
Function: Select the language for the set (Menu) mode selections.
Available Values: ENGLISH JAPANESE
Default: ENGLISH
Set Item 40 [ON TIMER] Function: Set the ON Timer time. Available
Values: OFF - 24:00 Default: OFF
The ON Timer turns on the radio at the programmed time.
Set Item 41 [CONTRAST]
Function: Setting of the Display contrast level.
Available Values: I ~ 10
Default: 5
Set Item 42 [MTR SYMB] Function: Select the S/PO meter Symbol.
Available Values: ». , . =. K -, CHR
Default: »
Set Item 43 [BARD DFST] Function: Correcting the atmospheric
pressure. Available Values: -500 ~ +500 hpa (mb) Default:
0 hpa (mb)
Set Item 44 [ALTI OFST] Function: Correcting the altimeter
setting. Available Values: 500 - t500 m Default: 0 m
68
VX-5R operating manual
OCl IVIUUC
Set Item 45 [DISP MODE]
Function: Select the display while the transceiver's power
is off
Available Values: NONE TEMP'BARO ALTI TEMP-BAROTEMP+ALTI
ALL
Default: NONE
NONE: No display when the transceiver is off.
TEMP: The current temperature will be displayed while the
transceiver's power is
off.
BARO: The current barometric pressure will be displayed while
the transceiver's
power is off.
ALTI: The current altitude will be displayed while the transceiver's
power is off
(calculated from the barometric pressure). TEMP+BARO: The
current temperature and barometric pressure will be displayed
while
the transceiver's power is off.
TEMP+ALTI: The current temperature and altitude will be displayed
while the
transceiver's power is off. ALL: The current temperature,
barometric pressure and altitude will be displayed
while the transceiver's power is off.
Disclaimer: The information on this site is provided as
a public service to the blind and visually handicapped community. While we have
done our best to ensure the information provided is accurate, please realize
the use of any information on this site is solely at your discretion and we
take no responsibility for use or attempted use of this information. |