Kenwood TMV-71A Manual INSTRUCTION MANUAL 144/440 MHz FM DUAL BANDER TM-V71A 144/430 MHz FM DUAL BANDER TM-V71A/ TM-V71E © B62-1926-00 (K, E, M4) 09 08 07 06 05 04 03 02 01 00 Information on Disposal of Old Electrical and Electronic Equipment (applicable for EU countries that have adopted separate waste collection systems) Products with the symbol (crossed-out wheeled bin) cannot be disposed as household waste. Old electrical and electronic equipment should be recycled at a facility capable of handling these items and their waste byproducts. Contact your local authority for details in locating a recycle facility nearest to you. Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on our health and the environment. Thank You We are grateful you decided to purchase this Kenwood FM transceiver. Kenwood always provides Amateur Radio products which surprise and excite serious hobbyists. This transceiver is no exception. Kenwood believes that this product will satisfy your requirements for both voice and data communications. FeaTures This transceiver has the following main features: · Enhanced Programmable Memory (PM) channels store virtually entire current operating environments for your quick recall. · Contains a total of 1000 Memory channels to program frequencies and other various data. Allows each Memory channel to be named using up to 8 alphanumeric characters. · Continuous Tone Coded Squelch System (CTCSS) or Digital Code Squelch (DCS) rejects unwanted calls from other stations. WriTing ConvenTions FolloWed in This Manual The writing conventions described below have been followed to simplify instructions and avoid unnecessary repetition. Instruction Action Press [KEY]. Momentarily press KEY. Press [KEY] (1s). Press and hold KEY for 1 second or longer. Press [KEY1], [KEY2]. Press KEY1 momentarily, release KEY1, then press KEY2. Press [F], [KEY]. Press the F key to enter Function mode, then press KEY to access its secondary function. Press [KEY] + Power ON. With the transceiver power OFF, press and hold KEY while turning the transceiver power ON. Notices to the User One or more of the followng statements may be applcable: FCC WARNING This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the nstructon manual. The user could lose the authorty to operate ths equpment f an unauthorzed change or modification is made. INFORMATION TO THE DIGITAL DEVICE USER REQUIRED BY THE FCC This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection aganst harmful nterference n a resdental nstallaton. This equipment generates, uses and can generate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the nterference by one or more of the followng measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer for techncal assstance. WHEN CONDENSATION OCCURS INSIDE THE TRANSCEIVER Condensation may occur inside the transceiver in such a case where the room is warmed using a heater on cold days or where the transceiver is quickly moved from a cold room to a warm room. When condensation occurs, the microcomputer and/or the transmit/receive circuits may become unstable, resulting in transceiver malfunction. If this happens, turn OFF the transceiver and just wait for a while. When the condensation droplets disappear, the transceiver will function normally. u EXPLOSIVE ATMOSPHERES (GASES, DUST, FUMES, etc.) Turn OFF your transceiver while taking on fuel or while parked in gasoline service stations. Do not carry spare fuel containers in the trunk of your vehicle if your transceiver is mounted in the trunk area. u INJURY FROM RADIO FREQUENCY TRANSMISSIONS Do not operate your transceiver when somebody is either standing near to or touching the antenna, to avoid the possibility of radio frequency burns or related physical injury. u DYNAMITE BLASTING CAPS Operating the transceiver within 150 m (500 feet) of dynamite blasting caps may cause them to explode. Turn OFF your transceiver when in an area where blasting is in progress, or where "TURN OFF TWO-WAY RADIO" signs have been posted. If you are transporting blasting caps in your vehicle, make sure they are carried in a closed metal box with a padded interior. Do not transmit while the caps are being placed into or removed from the container. PrecaUtioNs Observe the following precautions to prevent fire, personal injury, and transceiver damage. · When operating mobile, do not attempt to configure the transceiver while driving; it is too dangerous. · Do not transmit with high output power for extended periods. The transceiver may overheat. · Do not disassemble or modify the transceiver for any reason, unless instructed by this manual or by Kenwood documentaton. · Do not expose the transceiver to long periods of direct sunlight, nor place it near heating applances. · Do not place the transceiver in excessively dusty, humid, or wet areas, nor on unstable surfaces. · If an abnormal odor or smoke is detected coming from the transceiver, switch the transceiver power off immediately, and contact a Kenwood service station or your dealer. · Use of the transceiver while you are driving may be against traffic laws. Please check and observe the vehicle regulations in your area. · Be aware of local laws pertaining to the use of headphones/headsets while driving on public roads. If in doubt, do not wear a headset while mobiling. · Do not use options not specified by Kenwood. u The transceiver is designed for a 13.8 V DC (±15%) power source! Never use a 24 V battery to power the transceiver. Check the battery polarity and voltage of the vehicle before installing the transceiver. u Use only the supplied DC power cable or a Kenwood optional DC power cable. u Do not insert metal objects into the cooling fan. u Do not cut and/or remove the fuse holder on the DC power cable. Improper connections and/or current surges may cause smoke or fire. u For passenger safety, install the transceiver securely using the supplied mounting bracket and screw set so the transceiver will not break loose in the event of a collision. coNteNts PREPARATION ………………………………………………………………………..1 SUPPLIED ACCESSORIES …………………………………………………..1 MOBILE INSTALLATION ………………………………………………………1 POWER CABLE CONNECTION …………………………………………….2 ANTENNA CONNECTION……………………………………………………..5 FRONT PANEL ORIENTATION ……………………………………………..6 ACCESSORY CONNECTIONS ………………………………………………7 GETTING ACQUAINTED……………………………………………………………8 FRONT PANEL…………………………………………………………………….8 DISPLAY……………………………………………………………………………10 REAR PANEL…………………………………………………………………….12 SUB-PANEL ………………………………………………………………………12 MICROPHONE (MC-59) ………………………………………………………13 BASIC OPERATIONS………………………………………………………………14 SWITCHING THE POWER ON/ OFF …………………………………….14 ADjUSTING THE VOLUME …………………………………………………14 ADjUSTING THE SQUELCH……………………………………………….15 SELECTING A BAND………………………………………………………….15 SELECTING DUAL BAND MODE/ SINGLE BAND MODE ………16 SELECTING A FREQUENCY BAND …………………………………….17 SELECTING AN OPERATING MODE …………………………………..17 TRANSMITTING …………………………………………………………………19 MENU MODE ………………………………………………………………………….20 MENU ACCESS………………………………………………………………….20 MENU CONFIGURATION ……………………………………………………20 CHARACTER ENTRY …………………………………………………………24 OPERATING THROUGH REPEATERS……………………………………..26 REPEATER ACCESS………………………………………………………….26 TRANSMITTING A 1750 Hz TONE ……………………………………….30 REVERSE FUNCTION…………………………………………………………30 AUTOMATIC SIMPLEx CHECKER (ASC) …………………………….30 TONE FREQUENCY ID ……………………………………………………….31 iv MEMORY CHANNELS …………………………………………………………….32 SIMPLEx & REPEATER OR ODD-SPLIT MEMORY CHANNEL? ………………………………………………………..32 STORING SIMPLEx AND STANDARD REPEATER FREQUENCIES ………………………………………………………………….33 STORING ODD-SPLIT REPEATER FREQUENCIES ………………33 RECALLING A MEMORY CHANNEL ……………………………………34 CLEARING A MEMORY CHANNEL ……………………………………..35 NAMING A MEMORY CHANNEL …………………………………………35 SWITCHING THE MEMORY NAME/ FREQUENCY DISPLAY….36 MEMORY-TO-VFO TRANSFER……………………………………………36 CHANNEL DISPLAY FUNCTION………………………………………….36 PROGRAMMABLE MEMORY (PM)…………………………………………..38 PROGRAMMABLE INFORMATION ……………………………………..38 APPLICATION ExAMPLES …………………………………………………39 STORING DATA IN PM CHANNELS …………………………………….40 RECALLING PM CHANNELS ………………………………………………40 AUTO PM CHANNEL STORE………………………………………………41 PM CHANNEL RESET ………………………………………………………..41 SCAN …………………………………………………………………………………….42 SELECTING A SCAN RESUME METHOD …………………………….43 VFO SCAN…………………………………………………………………………43 MEMORY SCAN…………………………………………………………………44 GROUP SCAN……………………………………………………………………45 PROGRAM SCAN ………………………………………………………………46 MHz SCAN…………………………………………………………………………48 CALL SCAN……………………………………………………………………….48 CONTINUOUS TONE CODED SQUELCH SYSTEM (CTCSS) ……..49 USING CTCSS……………………………………………………………………49 CTCSS FREQUENCY ID……………………………………………………..51 DIGITAL CODED SQUELCH (DCS)…………………………………………..52 USING DCS ……………………………………………………………………….52 DCS CODE ID…………………………………………………………………….54 DUAL TONE MULTI-FREQUENCY (DTMF) ……………………………….55 MANUAL DIALING……………………………………………………………..55 v AUTOMATIC DIALER …………………………………………………………56 DTMF KEY LOCK……………………………………………………………….58 EchoLink MEMORY ………………………………………………………………..59 AUTOMATIC DIALER …………………………………………………………59 SETTING UP EchoLink MODE…………………………………………….61 AUxILIARY FUNCTIONS …………………………………………………………62 POWER-ON MESSAGE ………………………………………………………62 DISPLAY BRIGHTNESS ……………………………………………………..62 KEY LOCK…………………………………………………………………………63 KEY BEEP …………………………………………………………………………64 PROGRAMMABLE VFO ……………………………………………………..64 CHANGING THE FREQUENCY STEP SIzE…………………………..65 PROGRAMMABLE FUNCTION KEYS ………………………………….66 FREQUENCY DIRECT ENTRY …………………………………………….67 AUTOMATIC POWER OFF (APO)………………………………………..67 S-METER SQUELCH…………………………………………………………..68 ADVANCED INTERCEPT POINT (AIP) …………………………………68 SWITCHING FM/AM MODE …………………………………………………69 BEAT SHIFT ………………………………………………………………………69 SPEAKER MUTE………………………………………………………………..69 SELECTING AN OUTPUT POWER ………………………………………70 TIME-OUT TIMER (TOT) ……………………………………………………..70 ExTERNAL SPEAKER CONFIGURATION ……………………………71 MASKING A BAND …………………………………………………………….71 DISPLAY PARTITION BAR………………………………………………….72 WEATHER ALERT (K TYPE MODELS ONLY)……………………….73 PASSWORD PROTECTION…………………………………………………74 VGS-1 OPTIONAL VOICE GUIDE & STORAGE UNIT…………………75 VOICE ANNOUNCEMENTS…………………………………………………75 VOICE RECORDER…………………………………………………………….78 CROSS-BAND/ LOCKED-BAND OPERATION (K TYPE MODELS ONLY)………………………………………………………..81 REPEATER HOLD………………………………………………………………82 REPEATER ID ……………………………………………………………………82 vi Packet OPeratiOn …………………………………………………………….83 Data BanD………………………………………………………………………83 Data terminal SPeeD……………………………………………………83 Pc POrt SPeeD ……………………………………………………………….84 SQc OutPut Setting ……………………………………………………..84 WireleSS OPeratiOn (k tyPe mODelS Only)…………………..85 PreParatiOn ………………………………………………………………….85 cOntrOl OPeratiOn ……………………………………………………..86 tranSceiver reSet……………………………………………………………87 OPtiOnS ……………………………………………………………………………….89 cOnnecting the Pg-5g/ Pg-5h interface caBleS……..90 inStalling the Dfk-3D Panel kit ………………………………..90 cOnnecting the Pg-5f extenSiOn caBle …………………..92 inStalling the vgS-1 vOice guiDe unit………………………93 maintenance………………………………………………………………………94 general infOrmatiOn ………………………………………………….94 Service……………………………………………………………………………94 Service nOte………………………………………………………………….94 cleaning…………………………………………………………………………94 trOuBleShOOting…………………………………………………………95 SPecificatiOnS …………………………………………………………………..96 PREPARATION SuPPlIEd AccESSORIES Note: A market area code (K, E, or M4) can be found on the label attached to the package box. Item Part Number Quantity Microphone T9-0657-XX DC power cable (with 20 A fuses) K, M4 types E30-7628-XX E type E30-3452-XX Mounting bracket J29-0628-XX Screw set N99-033-XX Fuse (5 A) K, M4 types F5-0079-XX E type F52-0024-XX Warranty Card K, E types only —- Instruction manual B62-926-XX MOBIlE INSTAllATION Select a safe, convenient location inside your vehicle that will minimize danger to your passengers and yourself while the vehicle is in motion. Consider installing the transceiver under the dash in front of the passenger seat so that knees or legs will not strike the radio during sudden braking of your vehicle. Try to a pick well-ventilated location that is shielded from direct sunlight. Note: You may experience interference on your GPS receiver when using in or around 438.8 MHz (A band) and/or 443.8 MHz (B band). To eliminate the interference, ensure that the transceiver is installed at a location separate from your GPS receiver. 1 Install the mounting bracket in the vehicle using the supplied self-tapping screws and flat washers (4 of each are supplied). · The bracket can be mounted with the bracket opening facing down, for underdash mounting, or facing up. · The bracket must be installed so that the 3 screw slots on the edge of each bracket side are facing the back. Self-tapping screw (5 x 6 mm) Flat washer 2 2 Position the transceiver, then insert and tighten the supplied hexagon SEMS screws and flat washers (4 of each are supplied, 2 for each side of the bracket). · Ensure that all hardware is tightened, to prevent vehicle vibration from loosening the bracket or transceiver. · Set an appropriate angle for the main unit, using the 3 screw slots on the rear edge of each bracket side. POwER cABlE cONNEcTION n Mobile Operation Be sure to use a 12 V vehicle battery that has sufficient current capacity. If the current to the transceiver is insufficient, the display may darken during transmission or the transmit output power may drop excessively. Never connect the transceiver to a 24 V battery Note: If you use the transceiver for a long period when the vehicle battery is not fully charged or when the engine is OFF, the battery may become discharged and will not have sufficient reserves to start the vehicle. Avoid using the transceiver under these conditions. 1 Route the DC power cable supplied with the transceiver directly to the vehicle’s battery terminals using the shortest path from the transceiver. · When using a noise filter, it should be installed with an insulator to prevent it from touching metal on the vehicle. · We do not recommend using a cigarette lighter socket as some cigarette lighter sockets introduce an unacceptable voltage drop. · If the power cable must be routed through a hole in the vehicle chassis or body, for example in the firewall at the front of the passenger compartment, use a rubber grommet to protect the cable from abrasion. Dismantle the fuse holder to pass the cable through the firewall. · The entire length of the cable must be dressed so it is isolated from heat, moisture, and the engine secondary (high voltage) ignition system/ cables. SEMS screw 2 Afterthecableisinplace,windheat-resistanttapearoundthefuseholder toprotectitfrommoisture.Tiedownthefullrunofcable. 3 Topreventtheriskofshortcircuits,disconnectotherwiringfromthe negative(­)batteryterminalbeforeconnectingthetransceiver. 4 Confirmthecorrectpolarityoftheconnections,thenattachthepowercable tothebatteryterminals;redconnectstothepositive(+)terminalandblack connectstothenegative(­)terminal. · Usethefulllengthofthecablewithoutcuttingoffexcess,evenifthecableis longerthanrequired.Inparticular,neverremovethefuseholdersfromthecable. 5 Reconnectanywiringremovedfromthenegativeterminal. 6 ConnecttheDCpowercabletothetransceiver. · Presstheconnectorsfirmlytogetheruntilthelockingtabclicks. PassengercompartmentEnginecompartment Black(–)cable Red(+) cable Rubbergrommet Fuseholder(Etype) Fuseholder (K,M4types) Fuseholder (K,M4types) Fuseholder (Etype) 12Vvehicle battery DCpowercable n FixedStationOperation Inordertousethistransceiverforfixedstationoperation,youwillneeda separate1.8VDCpowersupplythatmustbepurchasedseparately.The recommendedcurrentcapacityofthepowersupplyis12A. Note: DonotplugtheDCpowersupplyintoanACoutletuntilyoumakeallconnections. EnsurethatthetransceiverandDCpowersupplyarebothOFF. ConnecttheDCpowercabletotheregulatedDCpowersupplyandensure thatthepolaritiesarecorrect(Red:positive,Black:negative). · UsethesuppliedDCpowercabletoconnectthetransceivertoaregulated powersupply.DonotdirectlyconnectthetransceivertoanACoutlet. · Donotsubstitutethecablewithsmallergaugewires. 4 3 ConnecttheDCpowercabletothetransceiver. · Presstheconnectorsfirmlytogetheruntilthelockingtabclicks. Note: Foryourtransceivertofullyexhibititsperformancecapabilities,werecommendusing anoptionalPS-(20.5A,25%dutycycle)powersupply. n ReplacingFuses Ifthefuseblows,determinethecause,thencorrecttheproblem.Afterthe problemisresolved,replacethefuse.Ifnewlyinstalledfusescontinueto blow,disconnectthepowercableandcontactyourauthorizedKenwood dealeroranauthorizedKenwoodservicecenterforassistance. Fuse Location Fuse Current Rating Transceiver (locatedontheDCconnector) 15A SuppliedDCpowercable 20A Onlyusefusesofthespecifiedtypeandrating;otherwisethetransceivercouldbedamaged. Black(–) cable Red(+) cable DCpowercable Fuseholder (K,M4types) Fuseholder (Etype) Fuseholder(Etype) Fuseholder (K,M4types) RegulatedDC powersupply Fuse holder (E type) Fuse holder (K, M4 types) Fuse Fuseholder Fuseholder Fuse 5 ANTENNA cONNEcTION Before operating, you must first install an efficient, well-tuned antenna. The success of your installation will depend largely on the type of antenna and its correct installation. The transceiver can give excellent results if the antenna system and its installation are given careful attention. Use a low-loss coaxial feed line that also has a characteristic impedance of 50 , to match the transceiver input impedance. Coupling the antenna to the transceiver via feed lines having an impedance other than 50 reduces the efficiency of the antenna system and can cause interference to nearby broadcast television receivers, radio receivers, and other electronic equipment. u Transmitting without first connecting an antenna or other matched load may damage the transceiver. Always connect the antenna to the transceiver before transmitting. u All fixed stations should be equipped with a lightning arrester to reduce the risk of fire, electric shock, and/or transceiver damage. To antenna Antenna terminal Feed line connector 6 FRONT PANEl ORIENTATION This transceiver allows you to change the orientation of the front panel. Depending on where/how you installed the transceiver you may wish to flip the front panel upside-down for easier operation. On the right side of the front panel, pull the panel release latch forward. Slide the front panel to the left, then pull it away from the main body of the transceiver. 3 Flip the front panel upside-down, then reattach it to the main body of the transceiver. 7 AccESSORy cONNEcTIONS n External Speakers If you plan to use external speakers, choose speakers with an impedance of 8 . The external speaker jacks accept a 3.5 mm (1/8") mono (2-conductor) plug. We recommend using SP-50B speakers. There are 2 speaker jacks on the rear of the transceiver: SP 1 and SP 2. Refer to page 7 to determine how the speakers will be used. n Microphone To communicate using voice, connect the supplied microphone to the MIC jack on the left side of the transceiver. Press firmly on the plug until the locking tab clicks. SP 1 jack SP 2 jack External speakers (SP-50B) Microphone connector MIC jack GETTING ACQUAINTED FroNT PANEl qVFO Press [VFO] to enter VFO mode {page 17}, then rotate the Tuning control to select an operating frequency. Press [VFO](1s) to start VFO scan {page 43}. Press [F],[VFO] to copy the current Memory channel or Call channel to the VFO (memory shift) {page 36}. w MR Press [MR] to enter Memory Channel mode {page 1}, then rotate the Tuning control to select a Memory channel. Press [MR](1s) to start Memory scan {page 44}. Select a Memory channel, then press [F],[MR] to store the current operating frequency in the Memory channel {page 33}. e TuningControl Rotate to select an operating frequency or Memory channel, change the scan direction, select a tone frequency, etc. Press [F], then press the Tuning control to enter Menu mode {page 20}. Press [MHz](1s) to start MHz scan {page 4} or Group scan {page 45}. r CALL Press [CALL] to select the Call channel. Press [CALL](1s) to start Call scan {page 4}. Press [F],[CALL] to store the current operating frequency to the Call channel {page 33}. t F Press [F] to enter Function mode. Press [F](1s) to turn the transceiver key lock function ON or OFF {page 63}. y TONE Press [TONE] to turn the Tone function ON. Continually press [TONE] to toggle the functions as follows: Tone ON >> CTCSS ON >> DCS ON >> OFF. While Tone, CTCSS, or DCS is ON, press [F],[TONE] to enter CTCSS or DCS setup mode. uREV Press[REV]toturntheReversefunctionONorOFF{page30}.Press[REV] (1s)toturntheAutomaticSimplexCheckerON{page30}.Press[F], [REV] toenterOffsetDirectionselectionmode.Eachtimeyoupress[F], [REV],the offsetdirectiontogglesasfollows: plus(+)direction­>minus(­)direction­>­7.6MHz(Etypeonly)­>OFF. iLOW Press[LOW]totogglethetransmitoutputpowerasfollows:HighPower(K, Etypesonly)­>MiddlePower­>LowPower{page70}.Press[F], [LOW]to turntheMutefunctionONorOFF{page6}, oPF1 Press[PF1]toactivateitsprogrammablefunction{page66}.Thedefault functionis"FrequencyBandSelect". !0PF2 Press[PF2]toactivateitsprogrammablefunction{page66}.Thedefault functionis"OperationBandSelect". !1BAND SEL (VOL) Control Rotatethe[BAND SEL]controltoadjustthespeakervolume{page14}. Presstheleft[BAND SEL]toselecttheAband.Presstheright[BAND SEL] toselecttheBband.Press[BAND SEL] (1s)totogglebetweensingleand dual-bandmode. !2SQL Control Rotatethe[SQL]controltoadjustthesquelchlevel.Clockwiseopensthe squelchandcounterclockwisetightensthesquelch{page68}. !3PM Press[PM]toentersthePM(ProgrammableMemory)channelselectionmode {page40}.Press[F], [PM]toenterPMChannelregistrationmode{page40}. !4 Press toturnthetransceiverpowerONandOFF. 10 DIsPlAy Indicator Description Appears when there is a transmission band available. Blinks when the cross-band repeater is ON (K type only). Appears when there is an operation band available. Blinks when the wireless remote control is ON (K type only). Appears when the Tone function is ON. Appears when the CTCSS function is ON. Appears when the DCS function is ON. Appears when the Shift function is set to plus. Appears when the Shift function is set to minus. Appears when the Reverse function is ON. Appears when the ASC function is ON. Blinks when the ASC function is performing an OK check. Appears while in AM mode. Appears while in Narrow FM mode. Appears when the selected channel is registered while in Memory Input mode. Displays the Memory channel and Menu number. Appears when the Memory Channel Lockout function is ON. Appears while using High output power. Blinks when the temperature protection circuit turns on. Appears while using Middle output power. Blinks when the temperature protection circuit turns on. Appears while using Low output power. Displays the operating frequency, Memory channel name, and Menu. Appears when receiving a busy signal. Performs as an S meter when receiving a signal and displays the selected power level while transmitting. Appears while transmitting. < A Band > < B Band > 11 Indicator Description Appears while using the data band. Appears when the data terminal is set as 600 (bps). Appears when the frequency is set to ***,***,250 Hz. Appears when the frequency is set to ***,***,500 Hz. Appears when the frequency is set to ***,***,750 Hz. Appears when the frequency is set to ***,***,333 Hz. Appears when the frequency is set to ***,***,666 Hz. Appears when the F key is pressed. Appears when mute has been turned ON. Appears while making a recording. Appears when using an EchoLink Memory channel. Appears when the Key Lock function is ON. Appears when making a PM call. Appears while in Menu mode and when the Tone/CTCSS/DCS code is selected. Blinks when recalling a PM channel and while writing to memory. Only the "1" will blink while recording or in playback mode. Appears while accessing the Menu. Blinks when recalling a PM channel and while writing to memory. Only the "2" will blink while recording or in playback mode. Appears when entering characters in Menu mode or entering a code. Blinks when recalling a PM channel and while writing to memory. Only the "3" will blink while recording or in playback mode Appears when entering characters in Menu mode or entering a code. Blinks when recalling a PM channel and while writing to memory. Only the "4" will blink while recording or in playback mode. Appears when entering characters in Menu mode or entering a code. Blinks when recalling a PM channel and while writing to memory. Appears when Weather Alert is ON. Blinks when receiving a signal (K type only). 12 rEAr PANEl qANT Connect an M-type (TM-V71A) or N-type (TM-V71E) external antenna to this terminal {page 5}. When making test transmissions, connect a dummy load in place of the antenna. The antenna system or load should have an impedance of 50 . w DATA Connect a TNC unit to this terminal, via a 6-pin mini DIN connector. e PC Connect a personal computer to this terminal, via an -pin mini DIN connector. r SP(SP1/SP2) If desired, connect 1 or 2 external speakers for clearer audio. These jacks accept 3.5 mm (1/") diameter, 2-conductor plugs {page 7}. Refer to page 71 to determine how the speakers will be used. sUb-PANEl qMIC Connect the supplied microphone to this jack {page 7}. w PanelTerminal When using an optional panel kit, attach the panel to this terminal using the cable that comes with the panel kit. MIC PANEL 13 Keypad serial data No Connection MIC, 600 impedance GND (MIC) PTT GND DC 8 V, 100 mA max No Connection Microphone (Mc-59) qPTTswitch Press and hold, then speak into the microphone to transmit. w DTMFkeypad Press these keys to make DTMF calls, enter frequencies, or enter characters. e CALL/A Functions the same as the transceiver front panel [CALL] key. This is also the PF4 key and can be reprogrammed with a programmable function {page 66}. r VFO/B Functions the same as the transceiver front panel [VFO] key. This is also the PF3 key and can be reprogrammed with a programmable function {page 66}. t MR/C Functions the same as the transceiver front panel [MR] key. This is also the PF2 key and can be reprogrammed with a programmable function {page 66}. y PF/D Press to toggle between bands A and B. This is also the PF1 key and can be reprogrammed with a programmable function {page 66}. u UP/DWN Functions the same as the transceiver Tuning control. MicrophoneJack 14 BASIC OPERATIONS SwITChINg ThE POwER ON/ OFF Press the switch to switch the transceiver ON. · The power on message momentarily appears on the display. · Ifthetransceiverpasswordprotectionhasbeenactivated{page74},youmustfirstenter your password before you can operate the transceiver. Press the switch again to switch the transceiver OFF. AdjuSTINg ThE VOlumE Rotate the [BAND SEL] (VOL) control of your selected band clockwise to increase the volume and counterclockwise to decrease the volume. Note: Some functions of this transceiver, such as the beep and voice announcements, have their own volume settings. Adjust those settings to your desired values. 15 AdjuSTINg ThE SQuElCh Squelch is used to mute the speaker when no signals are present. With the squelch level set correctly, you will hear sound only while actually receiving a signal. The higher the squelch level selected, the stronger the signals must be in order to hear them. Rotate the [SQL] control of your selected band, when no signals are present, and select the squelch level at which the background noise is just eliminated. SElECTINg A BANd Press the left [BAND SEL] control to select band A and the right [BAND SEL] control to select band B. · The icon appears at the top of the band on which you are operating and the icon appears at the top of the band on which you are currently set to transmit. Band A (left [BAND SEL] control): Band B (right [BAND SEL] control): 16 Pressing [PF2] allows you to switch the operating band between bands A and B, while maintaining the original band as the transmit band. Band A is the transmit band and band B is the operating band: Band A is both the transmit and operating band: SElECTINg duAl BANd mOdE/ SINglE BANd mOdE You can switch the transceiver between dual band operation and single band operation by pressing [BAND SEL] (1s) of your selected band. Dual band mode: Single band mode (band A only): (In Single band mode, you can turn the center partion bar display off {page 72}.) 17 SElECTINg A FREQuENCy BANd You can change the default frequency bands for bands A and B. Select band A or B by pressing the [BAND SEL] control or [PF2]. Press [F], [BAND SEL] of your selected band. · Each time you press [F], [BAND SEL], you cycle to the next frequency band. · The default setting of the [PF1] key also allows you to cycle to the next frequency band. · When masking a band {page 71}, you are restricted to using only the selectable band. · When receiving 2 signals on the same band, the image interference, senstivity, etc., performance will decrease. · Band A: 118 >> 144 (default) >> 220 >> 300 >> 430/440 (MHz). · Band B: 144 >> 220 >> 430/440 (default) >> 12000 (MHz). Note: u M4 type models do not have the following frequency bands available: 118, 220, 300, or 12000 (MHz). u E and M4 type models use the 430 MHz band and K type models use the 440 MHz band. SElECTINg AN OPERATINg mOdE There are 3 operating modes available to choose from: VFO mode, Memory Channel mode, and Call Channel mode. VFO mode VFO mode allows you to manually change the operating frequency. 1 Press [VFO] to enter VFO mode. 18 2 RotatetheTuningcontroltoselectyourdesiredoperatingfrequency. · Youcanalsoadjustthefrequencybyusingthemicrophone[UP]/[DWN]keys. · ThedefaultstepfrequencyfortheTuningcontrolvariesaccordingtothetype andoperatingband: Type 144 MHz 430/440 MHz K 5kHz 25kHz E 12.5kHz 25kHz M4 10kHz 10kHz · Toadjustthefrequencybyalargeramount,youcanpresstheTuningcontrol toenterMHzmode.WhileinMHzmode,rotatetheTuningcontroltoadjustthe frequencyinstepsof1MHz.PresstheTuningcontrolagaintoexitMHzmode andadjustthefrequencyusingthenormalstepfrequency. MemoryChannelMode MemoryChannelmodeallowsyoutoquicklyselectafrequentlyused frequencyandrelateddatawhichyouhavesavedinthetransceivermemory. Press[MR]toenterMemoryChannelmode. RotatetheTuningcontroltoselectyourdesiredMemorychannel. 19 Call Channel mode Call Channel mode allows you to quickly select a preset channel to allow immediate calls on that frequency. The Call channel can be conveniently used as an emergency channel within your group. 1 Select your desired band (A or B). · The Call channel has a dedicated frequency for both bands A and B. The default frequency for band A is 144 MHz. The default frequency for band B is 430/440 MHz. 2 Press [CALL] to enter Call Channel mode. · The C icon appears on the display. 3 Press [CALL] again to return to your previous operating frequency. TRANSmITTINg Select your desired band and frequency/channel. Press and hold the microphone [PTT] switch and speak into the microphone to transmit. · The icon and the RF power meter appear on the display for the selected transmit band. The RF power meter shows the relative transmit output power. · The / / icon(s) appear on the display, depending on what output power you have selected {page 70}. · Speak into the microphone in your normal voice, while keeping the microphone approximately 5 cm from your mouth. Speaking too close to the microphone or too loudly may increase distortion and reduce intelligibility of your signal at the receiving station. 3 Whenyoufinishspeaking,releasethe[PTT] switch. 20 MENU MODE Many functions on this transceiver are selected or configured through the Menu instead of physical controls. Once you become familiar with the Menu system, you will appreciate the versatility it offers. MENU AccEss 1 Press [F], Tuning control to access the Menu. · The Menu name and number appears on the display. 2 Rotate the Tuning control to select your desired Menu. 3 Press the Tuning control to set up the current Menu. 4 Rotate the Tuning control to select your desired value for the selected Menu. 5 Press the Tuning control to set the selected value. 6 Repeat steps 2 to 5 to set up additional Menus. · Press [CALL] (ESC) at any time to exit Menu mode. · Press [F] (BACK) at any time to cancel the Menu setup and return to the Menu selection. MENU cONfigUrAtiON Menu No. Display Description Setting Values Default Setting Ref. Page 000 BEEP Beep sound OFF/ ON ON 64 001 BP.VOL Beep volume level 1 ~ 7 5 64 002 EXT.SP External speaker output mode MODE 1/ MODE 2 MODE 1 71 003 1 ANN Voice announcement mode OFF/ AUTO/ MANUAL AUTO 75 004 1 ANN.LNG Voice announcement language ENG/ JPN ENG 77 005 1 ANN.VOL Voice announcement volume 1 ~ 7 5 77 21 Menu No. Display Description Setting Values Default Setting Ref. Page 006 1 ANN.SPD Voice announcement speed 0 ~ 4 1 77 007 1 PLAY.BK Recording playback repeat OFF/ ON OFF 80 008 1 P.BK.INT Playback repeat interval time 0 ~ 60 (seconds) 10 80 009 1 CON.REC Conversation recording OFF/ ON OFF 79 100 PRG.VFO Programmable VFO setup Varies with the selected frequency band ­ 64 101 STEP Step frequency Varies with the selected frequency band ­ 65 102 MODLAT Modulation/demodulation mode Varies with the selected frequency band ­ 69 103 VHF.AIP VHF band AIP OFF/ ON OFF 68 104 UHF.AIP UHF band AIP OFF/ ON OFF 68 105 S.SQL S-meter squelch OFF/ ON OFF 68 106 S.SQ.HNG S-meter squelch hangup time OFF/ 125/ 250/ 500 (ms) OFF 68 107 MUT.HNG Mute hangup time setup OFF/ 125/ 250/ 500/ 750/ 1000 (ms) OFF 70 108 B.SHIFT Beat shift OFF/ ON OFF 69 109 TOT Time-out timer 3/ 5/ 10 (minutes) 10 70 110 2 WX.ALT Weather alert OFF/ ON OFF 73 200 3 M.NAME Memory name setup Up to 6 characters ­ 35 201 RECALL Memory channel recall method ALL/ CURRENT ALL 34 202 3 L.OUT Memory channel lockout OFF/ ON OFF 44 203 GR.LINK Memory group link registration Up to 10 digits (0 ~ 9) ­ 45 204 ELK.MEM EchoLink memory setting Up to 8 characters for EchoLink memory ­ 59 205 ELK.SPD EchoLink memory transmission speed FAST/ SLOW FAST 60 300 DT.HOLD DTMF transmission hold OFF/ ON OFF 55 22 Menu No. Display Description Setting Values Default Setting Ref. Page 301 DT.MEM DTMF memory Up to 8 characters for DTMF memory name Up to 16 characters for DTMF code ­ 56 302 DT.SPD DTMF memory transmission speed FAST/ SLOW FAST 57 303 DT.PAUS DTMF pause code time 100/ 250/ 500/ 750/ 1000/ 1500/ 2000 (ms) 500 58 304 DT.LOCK DTMF key lock OFF/ ON OFF 58 400 OFFSET Offset frequency See reference page ­ 27 401 4 ARO Auto Repeater Offset OFF/ ON ON 29 402 1750.HD Transmission hold when transmitting a 1750 Hz tone OFF/ ON OFF 30 403 2 RPT.MOD Repeater mode CROSS/ A-TX/ B-TX CROSS 81 404 2 RPT.HLD Repeater transmission hold ON/ OFF OFF 82 405 2 RPT.ID Repeater ID registration Up to 6 characters ­ 82 406 2 ID.TX Repeater ID transmission OFF/ MORSE/ VOICE OFF 82 500 P.ON.MSG Power on message setup Up to 6 characters HELLO 62 501 BRIGHT Display brightness OFF/ 1 ~ 8 8 62 502 AUTO.BR Display auto brightness OFF/ ON OFF 62 503 COLOR Backlight color AMBER/ GREEN AMBER 63 507 PF1 PF1 key programmable function value See reference page FR.BAND 66 508 PF2 PF2 key programmable function value See reference page CTRL 66 509 MIC.PF1 Microphone PF1 key programmable function value See reference page A/B 66 510 MIC.PF2 Microphone PF2 key programmable function value See reference page MR 66 23 Menu No. Display Description Setting Values Default Setting Ref. Page 511 MIC.PF3 Microphone PF3 key programmable function value See reference page VFO 66 512 MIC.PF4 Microphone PF4 key programmable function value See reference page CALL (K/ M4 types) 1750 (E types) 66 513 MIC.LCK Microphone key lock OFF/ ON OFF 63 514 SC.RESM Scan resume method TO/ CO/ SEEK TO 43 516 APO Auto Power Off time OFF/ 30/ 60/ 90/ 120/ 180 (minutes) 180 67 517 DAT.BND Data Band mode A/ B/ ATX.BRX/ ARX.BTX A 83 518 DAT.SPD Data communications speed 1200/ 9600 (bps) 1200 83 519 PC .SPD PC terminal baud rate speed 9600/ 19200/ 38400/ 57600 (bps) 9600 84 520 SQC.SRC SQC output type OFF/ BUSY/ SQL/ TX/ BUSY.TX/ SQL.TX BUSY.TX 84 521 AUTO.PM Automatic PM entry OFF/ ON ON 41 522 2 REM.ID Personal Identificaton Number 000 ~ 999 000 85 523 2 ANS.BK Answer back OFF/ ON ON 85 527 DP.BAR Display partition bar OFF/ ON ON 72 998 PROTEC Password protection OFF/ ON OFF 74 999 RESET Reset VFO/ PART/ PM/ FULL VFO 88 1 Menu numbers 03 ~ 09 are available only when the optional VGS-1 unit is installed in the transceiver. 2 Menu numbers 110, 403 ~ 406, 522, and 523 are available only for K type models. 3 Menu numbers 200 and 202 are available only if a Memory Channel has been stored in the transceiver. 4 Menu number 401 is available only for K and E type models. 24 chArActEr ENtry Certain menus require you to enter characters, such as the power on message and memory names. When character entry is required, a cursor will appear on the display. 1 Press the Tuning control. · The cursor will blink. 2 Rotate the Tuning control to select your desired character. · You can enter characters as described below: – Power on message, memory name, DTMF memory name, and repeater ID (K type only): 0 ~ 9, A ~ Z, -, /, @, and space – EchoLink memory: 0 ~ 9, A ~ Z, and space – DTMF memory: 0 ~ 9, A ~ F, and space – Memory group link and wireless remote ID (K type only): 0 ~ 9 3 Press the Tuning control to set the selected character. · The cursor will move to the next digit. · You can move the cursor to the left or right by pressing [REV] ( ) or [LOW] ( ). · You can delete the selected character by pressing [PF1] (CLR). 4 Repeat steps 2 and 3 to enter the remaining characters. · Press [CALL] (ESC) at any time to exit Menu mode. · Press [TONE] (BACK) at any time to cancel the Menu setup and return to the Menu selection. 25 n Microphone Keypad character Entry The microphone keys can also be used to enter characters. Refer to the table below for characters corresponding to microphone keys. Key Character Display (with each press of the key) Q Z 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 P R S 7 T U V 8 W X Y 9 (space) 0 Not used # ­ / @ The microphone [A] ~ [D] keys have special functions assigned to them: [A]: Functions the same as [PF1] (CLR) [B]: Functions the same as [REV] ( ) [C]: Functions the same as [LOW] ( ) [D]: Functions the same as the Tuning control 26 OPERATING THROUGH REPEATERS Repeaters are often installed and maintained by radio clubs, sometimes with the cooperation of local businesses involved in the communications industry. Compared to simplex communication, you can usually transmit over much greater distances by using a repeater. Repeaters are typically located on mountain tops or other elevated locations. They generally operate at higher ERP (Effective Radiated Power) than a typical station. This combination of elevation and high ERP allows communications over considerable distances. REPEATER AccESS Most repeaters use a receive and transmit frequency pair with a standard or non-standard offset (odd-split). In addition, some repeaters must receive a tone from the transceiver in order to gain access to the repeater. For details, consult your local repeater reference. n Selecting an Offset Direction The offset direction allows your transmit frequency to be higher (+) or lower (­) than the receive frequency. Select your desired band (A or B). Press [F], [REV] (1s) to select an offset direction. · Each time you press [F], [REV] (1s), the offset direction changes as follows: Simplex operation >> + >> ­ >> Simplex operation TX: 144.725 MHz TX tone: 88.5 Hz RX: 145.325 MHz TX: 144.725 MHz TX tone: 88.5 Hz RX: 145.325 MHz 27 · If you are using an E-market transceiver, when operating on the 430 MHz band, the offset direction changes as follows: Simplex operation >> + >> ­ >> = (­7.6 MHz) >> Simplex operation If the offset transmit frequency falls outside the allowable range, transmitting is inhibited. Use one of the following methods to bring the transmit frequency within the band limits: · Move the receive frequency further inside the band. · Change the offset direction. Note: While using an odd-split memory channel or transmitting, you cannot change the offset direction. n Selecting an Offset Frequency The offset frequency is the value which the transmit frequency will be offset from the receive frequency. The default offset frequency on the 144 MHz band is 600 kHz for all market versions. The default on the 430/440 MHz band is 5 MHz. Select your desired band (A or B). Enter Menu mode and access Menu 400 (OFFSET) {page 20}. Set the appropriate offset frequency value. · The selectable range is from 00.00 MHz to 29.95 MHz, in steps of 50 kHz. Note: After changing the offset frequency, the new offset frequency will also be used by Automatic Repeater Offset {page 29}. n Activating the Tone Function To turn the Tone function on: Select your desired band (A or B). Press [TONE] to turn the Tone function ON. · Each time you press [TONE], the selection changes as follows: None >> T (Tone) >> CT (CTCSS) >> DCS (DCS) >> None Note: When accessing a repeater that requires a 1750 Hz tone, you do not need to activate the Tone function. Simply press the key assigned to the 1750 Hz tone {page 66} to transmit the tone. 28 n Selecting a Tone Frequency To select the tone frequency required to access your desired repeater: Turn the Tone function ON. Press [F], [TONE]. · The current tone frequency appears on the display. The default frequency is 88.5 Hz. 3 Rotate the Tuning control to select your desired frequency. · To exit the tone frequency selection, press [F] (ESC). 4 Press any key other than the Tuning control and [F] (ESC) to set the selected frequency. Note: If you have set up a Memory channel with a tone setting, simply recall the Memory channel instead of setting up the tone frequency every time. No. Frequency (Hz) No. Frequency (Hz) No. Frequency (Hz) No. Frequency (Hz) 01 67.0 12 97.4 23 141.3 34 206.5 02 69.3 13 100.0 24 146.2 35 210.7 03 71.9 14 103.5 25 151.4 36 218.1 04 74.4 15 107.2 26 156.7 37 225.7 05 77.0 16 110.9 27 162.2 38 229.1 06 79.7 17 114.8 28 167.9 39 233.6 07 82.5 18 118.8 29 173.8 40 241.8 08 85.4 19 123.0 30 179.9 41 250.3 09 88.5 20 127.3 31 186.2 42 254.1 10 91.5 21 131.8 32 192.8 11 94.8 22 136.5 33 203.5 29 n Automatic Repeater Offset (K and E Types Only) This function automatically selects an offset direction and activates the Tone function, according to the frequency that you have selected. To obtain an up- to-date band plan for repeater offset direction, contact your national Amateur Radio association. Enter Menu mode and access Menu 401 (ARO) {page 20}. Set the ARO to ON. Press [BAND SEL A] to select the A band. Press [VFO] to select VFO mode. Rotate the Tuning control to select your desired frequency. Press [PTT] to start a call. · You will be transmitting on an offset frequency value determined from your offset setting value {page 27} and an offset direction depending on your selected frequency. Refer to the settings below for offset directions: K Market: Under 145.100 MHz: No offset (Simplex operation) 145.100 ~ 145.499 MHz: Minus (­) offset 145.500 ~ 145.599 MHz: No offset (Simplex operation) 146.000 ~ 146.399 MHz: Plus (+) offset 146.400 ~ 146.599 MHz: No offset (Simplex operation) 146.600 ~ 146.999 MHz: Minus (­) offset 147.000 ~ 147.399 MHz: Plus (+) offset 147.400 ~ 147.599 MHz: No offset (Simplex operation) 147.600 ~ 147.999 MHz: Minus (­) offset 148.000 MHz and higher: No offset (Simplex operation) E Market: Under 145.000 MHz: No offset (Simplex operation) 145.600 ~ 145.799 MHz: Minus (­) offset 145.800 MHz and higher: No offset (Simplex operation) 30 TRANSmITTING A 1750 Hz TONE Most repeaters in Europe require that a transceiver transmit a 1750 Hz tone. By turning the 1750 Hz tone menu item ON, the transceiver will automatically transmit the 1750 Hz tone for 2 seconds whenever you transmit. Enter Menu mode and access Menu 402 (1750HD) {page 20}. Set the tone to ON or OFF. · When set to ON, the 1750 Hz tone will transmit. When set to OFF, the tone will not be transmitted. REVERSE FUNcTION After setting a separate receive and transmit frequency, you can exchange these frequencies using the Reverse function. This allows you to manually check the strength of signals you receive directly from other stations, while using a repeater. If the station’s signal is strong, move to a simplex frequency to continue the contact and free up the repeater. Press [REV] to turn the Reverse function ON or OFF. · When the Reverse function is ON, the icon will appear on the display. Note: u If the transmit frequency is outside the allowable transmit frequency range when using Reverse, pressing [PTT] will cause an error tone to sound and transmission will be inhibited. u If the receive frequency is outside the receive frequency range when using Reverse, an error tone will sound and Reverse will not operate. u The ARO (Automatic Repeater Offset) will not function when Reverse is ON. u You cannot switch Reverse ON or OFF while transmitting. AUTOmATIc SImPlEx cHEcKER (ASc) While using a repeater, ASC periodically monitors the strength of signals you receive directly from the other stations. If the station’s signal is strong enough to allow direct contact without a repeater, the icon blinks. Press [REV] (1s) to turn the ASC ON. 31 · When the ASC is ON, the icon will appear on the display. · While direct contact is possible, without the use of a repeater, the icon will begin blinking. · To exit ASC, press [REV]. Note: u Pressing [PTT] will cause the icon to stop blinking. u ASC does not function if you are using simplex operation. u ASC does not function while scanning. u Activating ASC while using Reverse will switch the Reverse function OFF. u If you recall a Memory channel or the Call channel, and those channels are set up with the Reverse function switched ON, the ASC will switch OFF. u ASC causes received signals to be momentarily intermitted every 3 seconds. TONE FREqUENcy ID This function scans through all tone frequencies to identify the incoming tone frequency on a received signal. You can use this function to find which tone frequency is required by your local repeater. 1 Press [TONE] to switch the Tone function ON. · The icon appears on the display. 2 Press [F], [TONE] (1s) to run the Tone Frequency ID scan. · The icon blinks and SCAN appears on the display. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). · To quit the function, press [F] (ESC). · When the tone frequency is identified, the identified frequency appears on the display and blinks. Press any key other than the Tuning control while the identified frequency is blinking, to resume scanning. 3 Press the Tuning control to program the identified frequency in place of the currently set tone frequency. · The Tone function will remain ON. You can press [TONE] to switch the Tone function OFF. · Press [F] (ESC) if you do not want to program the identified frequency. 32 MEMORY CHANNELS In Memory channels, you can store frequencies and related data that you often use. Then you need not reprogram the data every time. You can quickly recall a programmed channel by simple operation. A total of 1000 Memory channels are available for bands A and B. SIMPLEX & REPEATER OR ODD-SPLIT MEMORY CHANNEL? You can use each memory channel as a simplex & repeater channel or as an odd- split channel. Store only one frequency to use as a simplex & repeater channel or two separate frequencies to use as an odd-split channel. Select either application for each channel depending on the operations you have in mind. Simplex & repeater channels allow: · Simplex frequency operation · Repeater operation with a standard offset (if an offset direction is stored) Odd-split channels allow: · Repeater operation with a non-standard offset The data listed below can be stored in each Memory channel: Parameter Simplex & Repeater Odd-split Receive frequency Yes Yes Transmit frequency Yes Receive frequency step size Yes Yes Transmit frequency step size Yes Offset direction Yes No Tone ON/OFF Yes Yes Tone frequency Yes Yes CTCSS ON/OFF Yes Yes CTCSS frequency Yes Yes DCS ON/OFF Yes Yes DCS code Yes Yes Reverse ON/OFF Yes No Memory channel lockout Yes Yes Memory channel name Yes Yes Modulation/Demodulation mode Yes Yes 33 STORINg SIMPLEX AND STANDARD REPEATER FREquENCIES Press [VFO] to enter VFO mode. Rotate the Tuning control to select your desired frequency. · Additionally, you can press the microphone [UP]/[DWN] keys to select a frequency. 3 Set up any additional data desired for the frequency. · Offset direction, Tone ON/OFF, Tone frequency, CTCSS ON/OFF, CTCSS frequency, DCS ON/OFF, DCS code, etc. 4 Press [F]. · A memory channel number appears. 5 Rotate the Tuning control to select your desired channel number. · Additionally, you can press the microphone [UP]/[DWN] keys to select a channel. 6 Press [MR] to store the data in the selected Memory channel. Note: If you store the data in a Memory channel that already has data stored in it, the old data will be cleared and the new data will be stored. n Call Channel Memory (Simplex) The Call channel can be used to store any frequency and related data that you will recall often. You may want to dedicate the Call channel as an emergency channel within your group. To store a simplex frequency and related data as the Call channel instead of in a Memory channel, after step 4 (above), press [CALL]. Note: Storing new data in the Call channel will clear the old data. (The Call channel itself cannot be cleared, but data can be replaced with new data.) STORINg ODD-SPLIT REPEATER FREquENCIES Some repeaters use a receive and transmit frequency pair with a non-standard offset. To access those repeaters, store two separate frequencies in a memory channel. You can then operate on those repeaters without changing the offset frequency you stored in the menu. 1 Set up a simplex channel by following steps 1 to 6 of "STORING SIMPLEX AND STANDARD REPEATER FREQUENCIES", above. 2 Press [VFO] to enter VFO mode. 3 Rotate the Tuning control to select your desired transmit frequency. · Additionally, you can press the microphone [UP]/[DWN] keys to select a frequency. 34 4 Set up any additional data desired for the transmit frequency. · Tone ON/OFF, Tone frequency, CTCSS ON/OFF, CTCSS frequency, DCS ON/OFF, DCS code, etc. 5 Press [F]. · A memory channel number appears. 6 Rotate the Tuning control to select your desired channel number. · Additionally, you can press the microphone [UP]/[DWN] keys to select a channel. 7 Press [PTT], [MR] to store the data in the selected Memory channel. n Call Channel Memory (Odd-Split) The Call channel can be used to store any frequency and related data that you will recall often. You may want to dedicate the Call channel as an emergency channel within your group. To store an odd-split frequency and related data as the Call channel instead of in a Memory channel, after step 6 (above), press [PTT], [CALL]. Note: You cannot store the transmit offset status and Reverse status in an odd-split Call channel. RECALLINg A MEMORY CHANNEL Press [MR] to enter Memory Recall mode. Rotate the Tuning control to select your desired Memory channel. · Additionally, you can press the microphone [UP]/[DWN] keys to select a channel, or you can enter a channel number using the microphone keypad. The transceiver Menu also provides you with the option to recall Memory channels with storedfrequencies in your current band, or all Memory channels: Enter Menu mode and access Menu 201 (RECALL) {page 20}. Set the recall method to CURENT (current band) or ALL (all bands). · CURENT allows you to recall only those memory channels that have stored frequencies within the current band. ALL allows you to recall all programmed memory channels (such as recalling a 144 MHz frequency channel when operating in the 430/440 MHz band). 35 CLEARINg A MEMORY CHANNEL Press [MR] to enter Memory Recall mode. Rotate the Tuning control to select your desired Memory channel. · Additionally, you can press the microphone [UP]/[DWN] keys to select a channel, or you can enter a channel number using the microphone keypad. 3 Turn the transceiver power OFF. 4 Press [MR] + Power ON. · Aconfirmationmessageappearsonthedisplay. 5 Press the Tuning control to clear the Memory channel. · To exit without clearing the channel, press [F] (ESC). NAMINg A MEMORY CHANNEL You can name Memory channels using up to 6 alphanumeric characters. When you recall a named Memory channel, its name appears on the display instead of the stored frequency. Names can be call signs, repeater names, cities, people, etc. Press [MR] to enter Memory Recall mode. Rotate the Tuning control to select your desired Memory channel. Enter Menu mode and access Menu 200 (MNAME) {page 20}. Enter your desired name for the channel {page 24}. Note: You can overwrite a Memory channel name by performing the steps above. You can also clear a Memory channel name by clearing the Memory channel. 36 SwITCHINg THE MEMORY NAME/ FREquENCY DISPLAY After storing memory names, you can switch the display between the memory nameandthestoredfrequency.Thiscanbeusefulifyouneedtoconfirmthe frequency stored in named Memory channels. Press [MR] to enter Memory Recall mode. Press the Tuning control to toggle between the memory name and the stored frequency. <–> MEMORY-TO-VFO TRANSFER Transferring the contents of a Memory channel or the Call channel to the VFO can be useful if you want to search for other stations or a clear frequency, near the selected Memory channel or Call channel frequency. 1 Press [MR] or [CALL] to enter Memory Recall mode or select the Call channel. 2 Rotate the Tuning control to select your desired channel. (This step is not necessary when selecting the Call channel.) 3 Press [F], [VFO]. · The entire contents of the Memory channel or Call channel are copied to the VFO, and VFO mode is selected after the transfer is complete. · When copying a transmit frequency from an odd-split Memory or Call channel, you mustfirstturntheReversefunctionONbeforepressing[F], [VFO]. CHANNEL DISPLAY FuNCTION When this function is switched ON, the transceiver displays only a Memory channel number instead of a frequency. Turn the transceiver power OFF. Press [LOW] + Power ON to turn the channel display ON or OFF. <–> Note: u If no Memory channels have saved data in them, channel display will not function. u If a channel has a stored name, the name will appear on the display in place of the channel number. u When using Channel Display, you cannot reset the transceiver. 37 While in Channel Display mode, the transceiver keys function as shown below: Key Name [KEY] [F], [KEY] [KEY] (1s) While Transmitting [KEY] + Power ON Power ON/ OFF Power ON/ OFF Power ON/ OFF Power ON/ OFF Power ON/ OFF PM PM Recall PM In ­ ­ ­ VFO VFO mode Memory to VFO copy VFO Scan ­ ­ MR MR mode Store in Memory channel Memory Scan ­ Memory Clear CALL Call mode Store in Call channel Call Scan ­ ­ F Function mode Exit Function mode Key Lock ­ Reset TONE Tone/ CTCSS/ DCS Tone/ CTCSS/DCS freq./code selection ­ ­ Repeater/ Cross/A-TX/ B-TX/OFF REV Reverse ON/OFF Shift ON/ OFF ASC ON/ OFF ­ ­ LOW Change output power Mute ­ Change output power Change channel display PF1 E/M4: Change frequency band K: Select the Weather channel ­ ­ ­ ­ PF2 Change control band ­ ­ ­ Turn EchoLink ON/OFF Tuning control Change between the freq. and CH name Menu mode MHz Scan/ Group Scan ­ ­ BAND SEL A A band Change the freq. band Change Single/Dual ­ Band Mask A BAND SEL B B band Change the freq. band Change Single/Dual ­ Band Mask B 38 PROGRAMMABLE MEMORY (PM) Programmable Memory (PM) stores virtually all settings currently set on the transceiver. This transceiver provides 5 PM channels to store 5 sets of transceiver configurations. Later, you can quickly recall any one of these channels, depending on the operations you have in mind or the operating environment. PROGRAMMABLE InfORMAtIOn The following programmable settings can be stored in each channel: · Memory name · Memory channel lockout · Channel Display mode · Repeater mode · Key lock · Password protection · Password · Memory channel/Call channel/Program scan memory · DTMF memory · EchoLink memory · Data communications speed · 10 MHz mode · Mic sensitivity · SQC data output 39 APPLIcAtIOn ExAMPLEs The following are examples of how you might use Programmable Memory. These examples may not represent applications useful to you, but you will understand the flexibility of this function. Situation: You share your transceiver with other members in your family or club. However, each individual has personal preferences for how they like to set various functions. You have to keep changing many settings each time you use the transceiver. Solution: Because 5 PM channels are available, up to 5 persons can separately program the transceiver and store their customized environment. Then each person can quickly change to his or her favorite settings, simply by recalling a PM channel. It is too much trouble to change back the settings after somebody else has reconfigured them. So this application may avoid having a feature-rich transceiver but never using many useful features. Situation: While operating mobile on the way to work every morning, you prefer a silent transceiver that does not interrup the morning calm. In addition, you feel that a bright display is useless in the sunlight. At night when driving home, you realize the Beep function truly does serve a purpose and you acknowledge it is nice to see a bright display after dark. Solution: In 2 PM channels, store the same operating data such as frequency, offset, tone, etcl, and store different settings for the Display brightness and Beep functions. Then you can quickly recall the best settings for day or night operation. Situation: You cannot figure out how to exit the current transceiver mode. Solution: Simply recall PM channel 1, which contains an exact copy of the transceiver default environment. You will not lose the contents of any memory channels. 40 stORInG DAtA In PM chAnnELs 1 Confirm that the following conditions have been satisfied: · The transceiver is in receive mode. · Scan is not being used. · Microphone Control is OFF. 2 Configure the transceiver with your desired settings. · For data that can be stored, refer to page 38. 3 Press [F], [PM]. · PM channel numbers 1 to 5 appear and blink at the bottom of the display. 4 Enter a channel number ([1] to [5]) corresponding to your desired PM channel. · The settings are stored in the PM channel. REcALLInG PM chAnnELs 1 Press [PM]. · PM channel numbers 1 to 5 appear on the bottom of the display. 2 Enter a channel number ([1] to [5]) corresponding to your desired PM channel. · The settings stored in the PM channel are recalled. · The selected channel number appears on the display. 41 AutO PM chAnnEL stORE After you recall a PM channel, this function automatically overwrites the current PM channel with the present operating environment when: · You recall another PM channel. · You press [PM]. · You switch the transceiver power OFF. Follow the steps below to activate the Auto PM storage function. Enter Menu mode and access Menu 521 (AUTOPM) {page 20}. Set AUTOPM to ON. PM chAnnEL REsEt To reset the PM channels to their default settings: Turn the transceiver power OFF. Press [F] + Power ON. Release [F]. Rotate the Tuning control and select PM. Press the Tuning control. · A confirmation message appears on the display. 6 Press the Tuning control again to reset the PM channels. · Press [TONE] (BACK) to return to the previous display. · To exit without resetting the PM channels, press [F] (ESC). 42 SCAN Scan is a useful feature for hands-off monitoring of your favorite frequencies. Becoming comfortable with all types of Scan will increase your operating efficiency. This transceiver provides the following types of scans: Scan Type Scan Range VFO Scan Scans all frequencies on the current band. Memory Scan Scans all frequencies stored in the Memory channels. Group Scan Scans the frequencies in the Memory channels which belong to the group you have specified. Program Scan Scans all frequencies within the programmed range, on the current band. MHz Scan Scans all frequencies within a 1 MHz range from the originating frequency. Call Scan Scans the Call channel as well as the currently selected VFO frequency or Memory channel. Note: u Adjust the squelch level before using Scan. Selecting a squelch level too low could cause Scan to stop immediately. u While using CTCSS or DCS, Scan stops for any signal received; however, you will hear audio only when the signal contains the same CTCSS tone or DCS code that you selected. u When using S-meter Squelch, Scan stops when the received signal strength matches or exceeds the S-meter setting. Scan resumes 2 seconds after the signal level drops below the S-meter setting. u Pressing and holding [PTT] causes Scan to temporarily stop if it is functioning on a non TX band. u Starting Scan switches the Automatic Simplex Checker OFF. 43 SELECTING A SCAN RESUME METHOD The transceiver stops scanning at a frequency or Memory channel on which a signal is detected. It then continues scanning according to which resume mode you have selected. You can choose one of the following modes. The default is Time-operated mode. · Time-Operated mode The transceiver remains on a busy frequency or Memory channel for approximately 5 seconds, and then continues to scan even if the signal is still present. · Carrier-Operated mode The transceiver remains on a busy frequency or Memory channel until the signal drops out. There is a 2 second delay between signal drop-out and scan resumption. · Seek mode The transceiver remains on a busy frequency or Memory channel even after the signal drops out and does not automatically resume scanning. Note: To temporarily stop scanning and monitor weak signals, press the microphone PF key assigned to the Monitor function {page 66}. Press the PF key again to resume scanning. Enter Menu mode and access Menu 514 (SC.RESM) {page 20}. Set the Scan Resume mode to TO (Time-Operated), CO (Carrier-Operated) or SEEK. VFO SCAN VFO Scan monitors all frequencies tunable on the band, using the current frequency step size. Select your desired band. Press [VFO] (1s). · Scan starts at the current frequency. · The 1 MHz decimal blinks while scanning is in progress. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN]. 3 To quit VFO Scan, press [VFO] again. 44 MEMORY SCAN Use Memory Scan to monitor all Memory channels programmed with frequency data. Select your desired band. Press [MR] (1s). · Scan starts at the current frequency. · The 1 MHz decimal blinks while scanning is in progress. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN]. 3 To quit Memory Scan, press [MR] again. Note: u At least 2 Memory channels must contain data and must not be locked out of scan. u The L0/U0 to L9/U9 Memory channels will not be scanned. u You can also start Memory Scan when in Channel Display mode. While Scan is paused on a channel, the channel number blinks. n Locking Out a Memory Channel You can select Memory channels that you prefer not to monitor while scanning. Press [MR], then rotate the Tuning control to select your desired channel. Enter Menu mode and access Menu 202 (L.OUT) {page 20}. Set the lockout to ON to lock the channel out of the scanning sequence. · To cancel lockout, set the lockout to OFF. · The icon appears on the display for a channel that has been locked out. Note: The L0/U0 to L9/U9 Memory channels cannot be locked out. 45 GROUP SCAN For the purpose of Group Scan, the 1000 Memory channels are divided into 10 groups, with each group containing 100 channels. Group Scan monitors only the 100 channels which belong to the specific group you are scanning. The channels are grouped as follows: Memory Group Channel Range Memory Group Channel Range 0 0 ~ 99 5 500 ~ 599 100 ~ 199 6 600 ~ 699 200 ~ 299 7 700 ~ 799 300 ~ 399 8 800 ~ 899 400 ~ 499 9 900 ~ 999 Press [MR], then rotate the Tuning control to select a channel in your desired group. 2 Press [MHz] (1s). · Scan starts at the current channel. · The 1 MHz decimal blinks while scanning is in progress. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN]. 3 To quit Group Scan, press [MHz] again. Note: u At least 2 Memory channels in the selected group must contain data and must not be locked out of scan. u You can also start Memory Scan when in Channel Display mode. While Scan is paused on a channel, the channel number blinks. n Memory Group Link Memory Group Link provides you with the ability to link 2 or more Memory channel groups together to act as a single group when scanning. You can link up to 6 separate groups together, or even add multiple instances of the same group to the group link, to ensure that one group is scanned more often than the other groups. Enter Menu mode and access Menu 203 (GR.LINK) {page 20}. Press the Tuning control. · The cursor will begin blinking. 46 3 Rotate the Tuning control to select a group to link. 4 Press the Tuning control to set the group and move the cursor to the right. · Press [TONE] (<) to move the cursor back or [LOW] (>) to move the cursor to the right. 5 Repeat steps 3 and 4 to link additional groups together. 6 When you have entered your desired groups, press [LOW] (>) to move the cursor to the right, then press the Tuning control to complete the entry and exit Menu mode. · If you have entered the maximum of 6 groups, simply press the Tuning control to complete the entry and exit Menu mode. PROGRAM SCAN Program Scan is identical to VFO Scan except that you select a frequency range for the scan. n Setting Scan Limits You can store up to 10 scan ranges in Memory channels L0/U0 to L9/U9. Select your desired band. Press [VFO]. Rotate the Tuning control to select your desired frequency for the lower limit. 4 Press [F]. · A memory channel number appears and blinks. 5 Rotate the Tuning control to select a channel from L0 to L9. 6 Press [MR] to set the channel number. · The lower limit is stored in the channel. 7 Rotate the Tuning control to select your desired frequency for the lower limit. 47 8 Press [F]. 9 Rotate the Tuning control to select a matching channel number from U0 to U9. · For example, if you selecte channel L3 in step 5, select channel U3 here. 10 Press [MR] to set the channel number. · The upper limit is stored in the channel. · To confirm the stored scan limits, press [MR], then select the L and U channels. Note: u The lower limit must be lower in frequency than the upper limit. u The lower and upper frequency step sizes must be equal. u The lower and upper limits must be selected on the same band. n Using Program Scan Select your desired band. Press [VFO]. Rotate the Tuning control to select a frequency within your desired scan range. 4 Press [VFO], (1s). · Scan starts at the current frequency. · The 1 MHz decimal blinks while scanning is in progress. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN]. 5 To quit Program Scan, press [VFO] again. Note: u If the step size differs between the lower limit and upper limit, VFO scan will begin instead of Program Scan. u If the current VFO frequency is within more than one Program Scan range, the range stored in the smallest channel number is used. 48 MHz SCAN MHz Scan monitors a 1 MHz segment of the band, using the current frequency step size. The current 1 MHz digit determines the limits of the scan. For example, if the current frequency is 145.400 MHz, then the scan range would be from 145.000 MHz to 145.995 MHz (the exact upper limit depends on the current frequency step size). Select your desired band. Press [VFO]. Rotate the Tuning control to select a frequency within your desired 1 MHz range. 4 Press and hold the Tuning control for 1 second to start scanning. · Scan starts at the current frequency. · The 1 MHz decimal blinks while scanning is in progress. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN]. 5 To quit MHz Scan, press the Tuning control again. CALL SCAN Use Call Scan to monitor both the Call channel and either the currently selected VFO frequency or the currently selected Memory channel. Select your desired VFO frequency or Memory channel. Press [CALL] (1s) to start Call Scan. · The 1 MHz decimal blinks while scanning is in progress. · When scanning a Memory channel, the Call channel on the same band as the selected Memory channel is used for scan. 3 To quit Call Scan, press [CALL] again. Note: The Memory channel selected is scanned even if it has been locked out of scan. 49 CONTINUOUS TONE CODED SQUELCH SYSTEM (CTCSS) You may sometimes want to hear calls only from specific persons. The Continuous Tone Coded Squelch System (CTCSS) allows you to ignore (not hear) unwanted calls from other persons who are using the same frequency. To do so, select the same CTCSS tone as selected by the other persons in your group. A CTCSS tone is subaudible and is selectable from among 42 standard tone frequencies. Note: CTCSS does not cause your conversation to be private. It only relieves you from listening to unwanted conversations. USING CTCSS Select your desired band. Press[TONE] 2 times to activate the CTCSS function. · The icon appears on the display when the CTCSS function is ON. · Eachpressof[TONE] changes the selection as follows: Tone (T) ­> CTCSS (CT) ­> DCS (DCS) ­> Off (no display). 3 Press[F], [TONE]. · The current CTCSS frequency appears on the display and blinks. 4 RotatetheTuning control to select your desired CTCSS frequency. · Refer to the table below for the available frequencies. · To exit the CTCSS frequency selection, press [F] (ESC). 5 Press any key other than the Tuning control and [F] (ESC)tocompletethe setting. 6 When you are called: The transceiver squelch opens only when the selected CTCSS tone is received. When you make a call: Press and hold [PTT], then speak into the microphone. · To cancel CTCSS, press [TONE] until CT no longer appears on the display. 50 You can also select a CTCSS frequency by using the microphone: Select your desired band. Press[TONE] 2 times to activate the CTCSS function. · The icon appears on the display when the CTCSS function is ON. · Eachpressof[TONE] changes the selection as follows: Tone (T) ­> CTCSS (CT) ­> DCS (DCS) ­> Off (no display). 3 Press[F], [TONE]. · The current CTCSS frequency appears on the display and blinks. 4 Press the key programmed as [ENTER]. 5 Enter a frequency reference number (01 ~ 42) using the microphone keypad. · Refer to the table below for frequencies and their reference numbers. 6 Press[ENTER] again to complete the setting. No. Frequency (Hz) No. Frequency (Hz) No. Frequency (Hz) No. Frequency (Hz) 01 67.0 12 97.4 23 141.3 34 206.5 02 69.3 13 100.0 24 146.2 35 210.7 03 71.9 14 103.5 25 151.4 36 218.1 04 74.4 15 107.2 26 156.7 37 225.7 05 77.0 16 110.9 27 162.2 38 229.1 06 79.7 17 114.8 28 167.9 39 233.6 07 82.5 18 118.8 29 173.8 40 241.8 08 85.4 19 123.0 30 179.9 41 250.3 09 88.5 20 127.3 31 186.2 42 254.1 10 91.5 21 131.8 32 192.8 11 94.8 22 136.5 33 203.5 51 CTCSS FREQUENCY ID This function scans through all CTCSS frequencies to identify the incoming CTCSS frequency on a received signal. You may find this useful when you cannot recall the CTCSS frequency that the other persons in your group are using. 1 Press[TONE] 2 times to activate the CTCSS function. · The icon appears on the display when the CTCSS function is ON. · Eachpressof[TONE] changes the selection as follows: Tone (T) ­> CTCSS (CT) ­> DCS (DCS) ­> Off (no display). 2 Press[F], [TONE] (1s). · The icon blinks and "SCAN" appears on the display. · Scan starts when a signal is received. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/[DWN]. · To quit the scan, press [F] (ESC). · When a CTCSS frequency is identified, the identified frequency appears on the display and blinks. 3 PresstheTuning control to program the identified frequency in place of the currently set CTCSS frequency. · The CTCSS function will remain ON. To cancel CTCSS, press [TONE] until CT no longer appears on the display. · Press[F] (ESC) if you do not want to program the identified frequency. · RotatetheTuning control while an identified frequency is blinking, to resume scanning. 52 DIGITAL CODED SQUELCH (DCS) Digital Code Squelch (DCS) is another application which allows you to ignore (not hear) unwanted calls. It functions the same way as CTCSS. The only differences are the encode/ decode method and the number of selectable codes. For DCS, you can select from 104 different codes. USING DCS Select your desired band. Press [TONE] 3 times to activate the DCS function. · The icon appears on the display when the DCS function is ON. · Each press of [TONE] changes the selection as follows: Tone (T) ­> CTCSS (CT) ­> DCS (DCS) ­> Off (no display). 3 Press [F], [TONE]. · The current DCS code appears on the display and blinks. 4 Rotate the Tuning control to select your desired DCS code. · Refer to the table below for the available codes. · To exit the DCS code selection, press [F] (ESC). 5 Press any key other than the Tuning control and [F] (ESC) to complete the setting. 6 When you are called: The transceiver squelch opens only when the selected DCS code is received. When you make a call: Press and hold [PTT], then speak into the microphone. · To cancel DCS, press [TONE] until DCS no longer appears on the display. 53 You can also select a DCS code by using the microphone: Select your desired band. Press [TONE] 3 times to activate the DCS function. · The icon appears on the display when the DCS function is ON. · Each press of [TONE] changes the selection as follows: Tone (T) ­> CTCSS (CT) ­> DCS (DCS) ­> Off (no display). 3 Press [F], [TONE]. · The current DCS code appears on the display and blinks. 4 Press the key programmed as [ENTER]. 5 Enter your desired DCS code using the microphone keypad. · Refer to the table below for DCS codes. 6 Press [ENTER] again to complete the setting. DCS Code 023 025 026 031 032 036 043 047 051 053 054 065 071 072 073 074 114 115 116 122 125 131 132 134 143 145 152 155 156 162 165 172 174 205 212 223 225 226 243 244 245 246 251 252 255 261 263 265 266 271 274 306 311 315 325 331 332 343 346 351 356 364 365 371 411 412 413 423 431 432 445 446 452 454 455 462 624 465 466 503 506 516 523 565 532 546 565 606 612 624 627 631 632 654 662 664 703 712 723 731 732 734 743 754 54 DCS CODE ID This function scans through all DCS codes to identify the incoming DCS code on a received signal. You may find it useful when you cannot recall the DCS code that the other persons in your group are using. 1 Press [TONE] 3 times to activate the DCS function. · The icon appears on the display when the DCS function is ON. · Each press of [TONE] changes the selection as follows: Tone (T) ­> CTCSS (CT) ­> DCS (DCS) ­> Off (no display). 2 Press [F], [TONE] (1s). · The icon blinks and "SCAN" appears on the display. · Scan starts when a signal is received. · To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN]. · To quit the scan, press [F] (ESC). · When a DCS code is identified, the identified code appears on the display and blinks. 3 Press the Tuning control to program the identified code in place of the currently set DCS code. · The DCS function will remain ON. To cancel DCS, press [TONE] until DCS no longer appears on the display. · Press [F] (ESC) if you do not want to program the identified code. · Rotate the Tuning control while an identified code is blinking, to resume scanning. 55 DUAL TONE MULTI-FREQUENCY (DTMF) The keys on the microphone keypad function as DTMF keys; the 12 keys found on a push-button telephone plus 4 additional keys (A, B, C, D). This transceiver provides 10 dedicated memory channels. You can store a DTMF number with up to 16 digits, along with a memory name of up to 8 digits in each of the channels to recall later for a quick call. Some repeaters in the U.S.A. and Canada offer a service called Autopatch. You can access the public telephone network via such a repeater by sending DTMF tones. For further information, consult your local repeater reference. MANUAL DIALINg Manual Dialing requires only two steps to send DTMF tones. Press and hold the microphone [PTT]. Press the keys in sequence on the keypad to send DTMF tones. · The corresponding DTMF tones are transmitted. · If the DTMF Hold function is activated, you need not hold down [PTT] while pressing keys. After transmitting the first tone (by pressing [PTT] and the first key), pressing additional keys will keep the transceiver in transmit mode for 2 seconds. Frequency (Hz) 1209 1336 1447 1633 697 [1] [2] [3] [A] 770 [4] [5] [6] [B] 852 [7] [8] [9] [C] 941 [ ] [0] [#] [D] n DTMF Hold Activate this function to remain in transmit mode, after beginning to press keys when making a call. Enter Menu mode and access Menu 300 (DT.HOLD) {page 20}. Set DTMF Hold to ON to continue transmitting when pressing keys. · Set this menu to OFF to stop the 2 second continuous transmission. 56 AUTOMATIC DIALER There are 10 dedicated DTMF Memory channels available to store DTMF numbers. You can store up to 16 digits in each channel. n Storing a DTMF Number in Memory Enter Menu mode and access Menu 301 (DT.MEM) {page 20}. Rotate the Tuning control to select a channel number. Press the Tuning control to set the selected channel number. · The name entry display appears. 4 Enter a name for the channel {page 24}, the press the Tuning control to set it. · The number entry display appears. 5 Enter a DTMF number for the channel {page 24}, then press the Tuning control to set it. 57 n Transmitting Stored DTMF Numbers Press and hold the microphone [PTT]. While transmitting, press the Tuning control. · The last called DTMF Memory channel name and number appear on the display. If no name has been saved for the channel, the DTMF code appears. 3 While still transmitting, rotate the Tuning control to select your desired DTMF Memory channel, then press the Tuning control to set the channel. · Additionally, you can press a DTMF key corresponding to your desired channel ([0] ~ [9]) to select the channel and begin transmission. · The stored DTMF number scrolls across the display and is transmitted. · The number will be transmitted even if you release [PTT] before the entire number has scrolled across the display. · If no DTMF number is stored in the selected channel, the frequency display is restored. n Selecting a Transmit Speed Some repeaters may not respond correctly if a DTMF number is transmitted at fast speed. If this happens, change the DTMF number transmission speed from FAST (default) to SLOW. Enter Menu mode and access Menu 302 (DT.SPD) {page 20}. Set the speed to FAST or SLOW. 58 n Selecting a Pause Duration You can change the pause duration stored in DTMF Memory channels; the default is 500 msec. Enter Menu mode and access Menu 303 (DT.PAUS) {page 20}. Select a speed (in msec) from the available list: 100/ 250/ 500/ 750/ 1000/ 1500/ 2000. DTMF KEY LOCK This function will lock the DTMF transmission keys so that they will not transmit if they are accidentally pressed. To lock the DTMF keys, turn this function ON. Enter Menu mode and access Menu 304 (DT.LOCK) {page 20}. Set the key lock to ON or OFF. 59 EchoLink MEMORY AutOMAtic DiALER There are 10 dedicated EchoLink Memory channels available. You can store up to 8 characters in each channel. n Storing EchoLink Memory Enter Menu mode and access Menu 204 (ELK.MEM) {page 20}. Rotate the Tuning control to select an EchoLink channel number from EL0 ~ EL9. 3 Press the Tuning control to set the selected channel number. · The call sign entry display appears. 4 Enter the call sign for the channel {page 24}, then press the Tuning control to set it. n transmitting EchoLink Memory Select the band and frequency of the node to which you want to connect. Press and hold the microphone [PTT]. While transmitting, press the Tuning control. · The last called Echolink/DTMF Memory channel name and number appears on the display. 60 4 While still transmitting, rotate the Tuning control to select your desired EchoLink Memory channel, then press the Tuning control to set the channel. · The stored code scrolls across the display and is transmitted. · The code will be transmitted even if you release [PTT] before the entire code has scrolled across the display. · The DTMF code of the changed Call Sign appears on the display. The Call Sign code is automatically preceeded with a "C" and ends with a "#". DTMF values are listed in the following table: 1 2 3 4 5 6 7 8 9 0 0 1 2 3 4 5 6 7 8 9 0 Q A D G J M P T W Z B E H K N R U X C F I L O S V Y So, for example, if the Call Sign being transmitted was JA1YKX, the display would read: C 51 21 10 93 52 92 # · If no data is stored in the selected channel, the frequency display is restored. 61 n Selecting a transmit Speed Some repeaters may not respond correctly if a code is transmitted at fast speed. If this happens, change the EchoLink transmission speed from FAST (default) to SLOW. Enter Menu mode and access Menu 205 (ELK.SPD) {page 20}. Set the speed to FAST or SLOW. SEtting up EchoLink MODE When connected to a PC, you can set whether or not to use the RTS and CTS terminals for hard flow control, or the SQC and PKS terminals for EchoLink. Turn the transceiver power OFF. Press [PF2] + Power ON to turn EchoLink ON. · The icon appears on the display when EchoLink is ON. · To turn EchoLink OFF, press [PF2] + Power ON again. EchoLink Mode ON EchoLink Mode OFF TM-V71 PC TM-V71 PC TxD ­> RxD TxD ­> RxD RxD <­ TxD RxD <­ TxD SQC ­> CTS RTS ­> CTS PKS <­ RTS CTS <­ RTS GND <­> GND GND <­> GND Note: When in EchoLink mode, you cannot change to Repeater mode or Remote Control mode. 62 AUXILIARY FUNCTIONS POWER-ON MESSAGE Each time you switch the transceiver ON, "HELLO" (default) appears on the display for approximately 2 seconds. You can program your favorite message in place of the default message. Enter Menu mode and access Menu 500 (P.ON.MSG) {page 20}. Enter your desired message {page 24}. · Press [PF1] (CLR) to clear the entire message, if necessary. DISPLAY BRIGhTNESS You can manually change the display illumination to suit the lighting conditions where you are operating. Enter Menu mode and access Menu 501 (BRIGHT) {page 20}. Set your desired brightness level from 1 to 8, or OFF. · Press [PF1] (CLR) to clear the entire message, if necessary. n Auto Display Brightness When Auto Brightness is activated, the display will light up every time a key is pressed. Enter Menu mode and access Menu 502 (AUTO.BR) {page 20}. Set the Auto Brightness function to ON or OFF. 63 n Backlight Color You can manually change the display illumination to suit the lighting conditions where you are operating. Enter Menu mode and access Menu 503 (COLOR) {page 20}. Set the backlight color to AMBER or GREEN. KEY LOCK The Key Lock function ensures that your transceiver settings will remain unchanged if you accidentally press a key. When activated, the following functions can still be used: · [ ] · [PTT] · microphone [PF] To turn Key Lock ON or OFF, press [F] (1s). · When Key Lock is activated, the icon will appear on the display. n Microphone Key Lock The Microphone Key Lock function will lock the microphone PF (Progammable Function) keys. Enter Menu mode and access Menu 513 (MIC.LCK) {page 20}. Turn the Micrphone Key Lock function ON or OFF. 64 KEY BEEP You can turn the transceiver beep function ON or OFF as desired. Enter Menu mode and access Menu 000 (BEEP) {page 20}. Turn the beep function ON or OFF. · Even with the beep function turned OFF, the transceiver will emit a beep tone under the following conditions: 1) When Auto Power Off is activated, the transceiver will beep 1 minute before the power turns off. 2) After transmitting for the maximum time duration according to the Time-out Timer, the transceiver will beep n Beep Volume Each time you press a key, the beep tone will sound. If you have left the beep function turned ON, you may wish to adjust the volume level of the beep. Enter Menu mode and access Menu 001 (BP.VOL) {page 20}. Set the beep volume to a level from 1 to 7. · The default is level 5. PROGRAMMABLE VFO If you always check frequencies within a certain range, you can set upper and lower limits for frequencies that are selectable. For example, if you select 144 MHz for the lower limit and 145 MHz for the upper limit, the tunable range will be from 145.000 MHz to 146.995 MHz. 1 Press the left or right [BAND SEL] to set band A or B as the operating band, then press [VFO]. 2 Enter Menu mode and access Menu 100 (PRG.VFO) {page 20}. (Example: E type) 65 3 Press the Tuning control. · The lower frequency limit blinks. 4 Rotate the Tuning control to select your desired lower frequency limit, then press the Tuning control to set the selected value. · The upper frequency limit blinks. · When setting the limit for the 1200 MHz band, the 1 MHz digit appears on the 7-segment display to the right of the main display. 5 Rotate the Tuning control to select your desired upper frequency limit, then press the Tuning control to set the selected value. 6 Press [CALL] (ESC) to exit Menu mode. Note: You cannot program the 100 kHz and subsequent digits. The exact 100 kHz and subsequent digits of the upper limit depend on the frequency step size you are using. ChANGING ThE FREqUENCY STEP SIzE Choosing the correct frequency step size is essential in selecting your exact frequency. The default step size on the 144 MHz band is 5 kHz (K type) or 12.5 kHz (E, M4 types). The default on the 430/440 MHz band is 25 kHz. For K type models, the default on the 118, 220, or 300 MHz band is 12.5 kHz and the default on the 1200 MHz band is 25 kHz. Press the left or right [BAND SEL] to select band A or B, then press [VFO]. Enter Menu mode and access Menu 101 (STEP) {page 20}. Set the step size to 5.0*, 6.25*, or 8.33 kHz (118 MHz band only) or to 10.0, *, 15.0, 20.0, 25.0, 30.0, 50.0, or 100.0 kHz. * These step sizes are not available for the 1200 MHz band. Note: Changing between step sizes may correct the displayed frequency. For example, if 144.995 MHz is displayed with a 5 kHz step size selected, changing to a 12.5 kHz step size corrects the displayed frequency to 144.9875 MHz. 66 PROGRAMMABLE FUNCTION KEYS n Transceiver Front Panel There are 2 PF (Programmable Function) keys on the transceiver front panel: PF1 and PF2. You can assign your own desired functions to these 2 keys. 1 Enter Menu mode and access Menu 507 (PF1) and/or Menu 508 (PF2) {page 20}. 2 Set your desired function for the key. Programmable functions available are: WX CH (Weather Channel)/ FR.BAND/ CTRL (Control)/ MONI (Monitor)/ VGS/ VOICE (Voice ON/OFF)/ GRP.UP/ MENU (Menu mode)/ MUTE (Speaker Mute)/ SHIFT (Shift)/ DUAL (Dual Mode)/ M>V (Memory to VFO Copy)/ 1750 (1750 Hz Tone). n Microphone Keys There are 4 microphone PF (Programmable Function) keys: [PF] (PF1), [MR] (PF2), [VF0] (PF3) and [CALL] (PF4). You can assign your own desired functions to these 4 keys. 1 Enter Menu mode and access Menu 509 (MIC.PF1) and/or Menu 510 (MIC. PF2) and/or Menu 511 (MIC. PF2) and/or Menu 512 (MIC. PF2) {page 20}. 2 Set your desired function for the key. Programmable functions available are: WX CH (Weather Channel)/ FR.BAND/ CTRL (Control)/ MONI (Monitor)/ VGS/ VOICE (Voice ON/OFF)/ GRP.UP/ MENU (Menu mode)/ MUTE (Speaker Mute)/ SHIFT (Shift)/ DUAL (Dual Mode)/ M>V (Memory to VFO Copy)/ VFO/ MR/ CALL/ MHz/ TONE/ REV (Reverse)/ LOW/ LOCK/ A/B (Band Select A/ Band Select B)/ ENTER/ 1750 (1750 Hz Tone). 67 FREqUENCY DIRECT ENTRY If the desired operating frequency is far from the current frequency, using the microphone keypad is the quickest way to change the frequency. One of the microphone PF keys must first be programmed as ENTER {page 66}, 1 Press the left or right [BAND SEL] to select band A or B, then press [VFO] or [CALL]. 2 Press the key programmed as [ENTER]. · The Direct Frequency Entry display appears. 3 Press the microphone keys ([0] ~ [9]) to enter your desired frequency. 4 To set the entered frequency, press [ENTER] or [VFO]. · Pressing [ENTER] before entering all of the digits will set the remaining digits to 0. · Pressing [VFO] before entering all of the digits will leave the remaining digits at their previous values. · Entering all digits for a frequency will automatically set the frequency without pressing [ENTER] or [VFO]. · If you need to only change the MHz digit, press the Tuning control, then enter the new value. AUTOMATIC POWER OFF (APO) Automatic Power Off is a background function that monitors whether or not any operations have been performed (keys pressed, Tuning control turned, etc.), and turns the transceiver power OFF if it has not been in use. Enter Menu mode and access Menu 516 (APO) {page 20}. Set the APO time limit to 30, 60, 90, 120, 180 minutes, or OFF. · After the time limit passes with no operations (default is 180 minutes), APO turns the transceiver power OFF. However, 1 minute before the power turns OFF, "APO" appears on the display and blinks, and a warning tone sounds. Note: If any settings are changed during while APO is ON, the timer resets. When you stop changing the settings, the timer begins counting again from 0. 68 S-METER SqUELCh S-meter Squelch causes the squelch to open only when a signal with the same or greater strength than the S-meter setting is received. This function relieves you from constantly resetting the squelch when receiving weak stations that you have no interest in. Enter Menu mode and access Menu 105 (S.SQL) {page 20}. Set the S-Meter squelch to ON or OFF. To select the desired S-meter setting, rotate the left (band A) or right (band B) SQL control depending on which band you have selected. · The squelch will open only at the level you have selected (for example, level 9). n Squelch hang Time When using S-meter Squelch, you may want to adjust the time interval between when the received signals drop and when the squelch closes. Enter Menu mode and access Menu 106 (S.SQ.HNG) {page 20}. Set the hang time to 125 or 500 ms, or OFF. ADVANCED INTERCEPT POINT (AIP) The VHF/UHF band is often crowded in urban areas. AIP helps eliminate interference and reduce audio distortion caused by intermodulation. You can use this function only while operating on the VHF/UHF band. 1 Enter Menu mode and access Menu 103 (VHF.AIP) and/or Menu 104 (UHF.AIP) {page 20}. 2 Set the AIP to ON or OFF. 69 SWITChING FM/AM MODE This transceiver is also capable of receiving (not transmitting) in AM on band A. The default mode on the 118 MHz band is AM while the default on the 144, 220, 300, or 430/440 MHz band is FM. Enter Menu mode and access Menu 102 (MODLAT) {page 20}. Set the mode to AM, FM, or NFM. Note: You cannot switch between FM and AM to receive on band B. BEAT ShIFT Since the transceiver uses a microprocessor to control various transceiver functions, the CPU clock oscillator’s harmonics or image may appear on some spots of the reception frequencies. In this case, we recommend you turn the Beat Shift function ON. Enter Menu mode and access Menu 108 (B.SHIFT) {page 20}. Set the Beat Shift to ON or OFF. SPEAKER MUTE While receiving or transmitting on the TX band, you may not want to hear audio received on the other band. Use this function to mute the speaker allocated to that band (not the TX band). While receiving, press [LOW] to switch the mute function ON or OFF. · The icon appears on the display when the function is ON. 70 n MuteHangTime WhenusingSpeakerMute,youmaywanttoadjustthetimeintervalbetween whenyoureceiveasignalandwhenthespeakerismuted. EnterMenumodeandaccessMenu107(MUT.HNG){page20}. Setthehangtimeto125,250,500,750,or1000ms. SelecTinganOuTpuTpOwer Itisagoodideatoselectlowertransmitpowerifcommunicationsisstillreliable. Thislowerstheriskofinterferingwithothersontheband.Whenoperatingfrom batterypower,youwillenjoymoreoperatingtimebeforearechargeisnecessary. Press[LOW]toselecthigh(H)(K,Etypesonly),medium(M),orlow(L)power. Thedefaultishigh. · YoucanprogramdifferentpowersettingsforbandsAandB. Note:Whenthetransceiveroverheatsbecauseofambienthightemperatureor continuoustransmission,theprotectivecircuitmayfunctiontolowertransmit outputpower. TiMe-OuTTiMer(TOT) Itissometimesnecessaryordesirabletorestrictasingletransmissiontoa specific maximum time. You may use this function to prevent repeater time-outs whenaccessingrepeaters,ortoconservebatterypower. WhenTOTtimesout(defaultis10minutes),thetransceivergeneratesbeepsand automaticallyreturnstoreceivemode.Toresumetransmitting,releaseandthen pressthemicrophone[PTT]again. EnterMenumodeandaccessMenu109(TOT){page20}. Setthetimerto3,5,or10minutes. 71 EXTERNAL SPEAKER CONFIGURATION This transceiver has two speaker jacks for external speakers, as well as an internal speaker. You can enjoy a variety of speaker configurations by using one or two external speakers. Received signals on bands A and B are output depending on how you want the internal and/or external speakers to function. Enter Menu mode and access Menu 002 (EXT.SP) {page 20}. Set the speaker mode to MODE 1 or MODE 2. · Refer to the table below for configurations based on the mode selected. Mode Speaker Setup Band Output Internal Speaker External SP1 External SP2 MODE 1 None A, B ­ ­ SP1 only x A, B ­ SP2 only A ­ B SP1, SP2 x A B MODE 2 None A, B ­ ­ SP1 only x A, B ­ SP2 only B ­ A SP1, SP2 x B A MASKING A BAND If you have no plans to use band A or B, you can hide the frequency display on the unused band. This saves power consumption and makes it simpler to read the information you need. Turn the transceiver power OFF. Press the left or right [BAND SEL] + Power ON. · The band mask display appears. 3 Rotate the Tuning control to select the band you want to hide (or return to normal). 72 4 Press the Tuning control to set the selected band. 5 Rotate the Tuning control to set the band to select USE or MASK. · USE allows you to see and use the band as normal. MASK hides the band on the display. 6 Press the Tuning control to set the selection. 7 Press the [CALL] (ESC) to exit. Note: You cannot operate the masked band nor use it to receive or transmit. DISPLAY PARTITION BAR The partition bar that appears between bands A and B can be removed if desired. Enter Menu mode and access Menu 527 (DP.BAR) {page 20}. Set the partition bar display to ON or OFF. 73 WEAThER ALERT (K TYPE MODELS ONLY) The Wealther Alert is available only in the USA and Canada. When activated, this function will check for a received NOAA 1050 Hz tone. When the tone is received, the weather alert tone will sound. Enter Menu mode and access Menu 110 (WX.ALT) {page 20}. Set the Weather Alert to ON or OFF. · When activated, the icon appears on the display. · When a signal is being received, the icon blinks. n Weather Channel Whether or not the Weather Alert is activated, you can still access the weather channels. The Weather Alert simply notifies you of activity on the weather channels. Press the key programmed with the WX function. Rotate the Tuning control to select your desired channel. Channel No. Frequency (MHz) Memory Name Location A1 162.550 WX 1 NOAA/ Canada A2 162.400 WX 2 NOAA/ Canada A3 162.475 WX 3 NOAA/ Canada A4 162.425 WX 4 NOAA A5 162.450 WX 5 NOAA A6 162.500 WX 6 NOAA A7 162.525 WX 7 NOAA A8 161.650 WX 8 Canada A9 161.775 WX 9 Canada A10 163.275 WX 10 ­ 74 PASSWORD PROTECTION If password protection is activated, you cannot operate the transceiver without first entering your password, after turning the transceiver power ON. Your password can be changed using the MCP control software. The password can contain up to 6 digits. When using the front panel keys, you can enter digits from 1 ~ 5. When using the microphone keypad, you can enter digits from 0 ~ 9 and A ~ F. Enter Menu mode and access Menu 998 (PROTEC) {page 20}. Set the password protection to ON or OFF. · When set to ON, "PASSWD" appears on the display. 3 Enter your password using the microphone keypad or the transceiver front panel keys. · When using the transceiver front panel keys, they operate as follows: [CALL]: 1 [F]: 2 [TONE]: 3 [REV]: 4 [LOW]: 5 4 After entering up to 6 digits, press the Tuning control to set the password. 75 VGS-1 OPTIONAL VOICE GUIDE & STORAGE UNIT When using the optional VGS-1 voice guide & storage unit, you gain access to the voice recorder and voice announcement functions. VOICE ANNOUNCEmENTS When changing modes, frequencies, settings, etc., an audio voice will announce the new information. Enter Menu mode and access Menu 003 (ANN) {page 20}. Set the announcement function to MANUAL, AUTO, or OFF. · Refer to the tables below for announcements based on settings. MANUAL: A microphone PF key must be programmed as [VOICE] to use MANUAL voice announcment. Operation Announcement While in VFO mode Press [VOICE]: Operating band frequency While in MR mode Press [VOICE]: "Channel" + Channel number + operating band frequency While in Call mode Press [VOICE]: "Call channel" + operating band frequency While in Menu mode Press [VOICE]: Menu number or setting value (some selections have no voice announcement) While setting up Tone/CTCSS/ DCS Press [VOICE]: Current frequency/code 76 AUTO: Announcements are made automatically when changing a mode/frequency/setting. Operation Announcement Press [VFO] "VFO" Press [MR] "MR" Press [CALL] "Call" Press [MENU] "Menu" + menu number Press [PM] "PM" Press [ENT] "Enter" Change the operating band/ turn the power ON "A"/"B" + "Channel" (for MR only) + "Call"/channel number + "Channel (for CALL only) + operating band frequency + output power level Change the frequency band New receive frequency Setting up the PM Channel number/"Off" Frequency direct entry Entered key number Memory Direct Entry mode Channel number Press [F] in VFO mode "Memory in" + channel number + frequency Press [F], [M.IN] in VFO mode "Memory in" + channel number + "Blank" Press [A/B] in VFO mode "A"/"B" + frequency + output power level Press [F] and then the Tuning control in VFO mode "Menu" + menu number Press the Tuning control in Menu mode Setting value Perform a Full Reset "Full reset?" Perform a Partial Reset "Partial reset?" Perform a VFO Reset "VFO reset?" Perform a PM Reset "PM reset?" Press [LOCK] (to turn the Lock function ON) "Lock on" Press [LOCK] (to turn the Lock function OFF) "Lock off" Tone frequency setup "Tone frequency" + frequency value CTCSS frequency setup "CTCSS frequency" + frequency value DCS code setup "DCS" + code value MHz step frequency setup "MHz Step" + frequency value 10 MHz setup "10" + "MHz setup" + frequency value Output power setup "TX Power" + power level 77 Voice Announcement Language Enter Menu mode and access Menu 004 (ANN.LNG) {page 20}. Set the language to ENG (English) or JPN (Japanese). Voice Announcement Volume Enter Menu mode and access Menu 005 (ANN.VOL) {page 20}. Set the announcement volume level from 1 to 7. · To turn the volume OFF, turn the announcement function OFF. Voice Announcement Speed Enter Menu mode and access Menu 006 (ANN.SPD) {page 20}. Set the announcement speed level from 0 to 4. · The speed settings are as follows: 0: 0.85 times normal speed 1: Normal speed 2: 1.15 times normal speed 3: 1.30 times normal speed 4: 1.45 times normal speed 78 VOICE RECORDER The voice recorder provides you with 3 VGS channels for recording voice memos, along with a single VGS channel for recording conversations. You can also prepare automated message responses to received calls. Each recording can last for up to 30 seconds. Voice memos To record a voice memo, for later playback: Press the PF key programmed as [VGS]. Press and hold the key for the VGS channel number you want to store the memo in: [F] (1), [TONE] (2), or [REV] (3). · A beep will sound and the transceiver will enter Recording mode. 3 Press and hold the VGS channel number key again (the same key you pressed in the previous step), then speak into the microphone to record your memo. · Recording begins as soon as you press the VGS channel number key, and a timer appears on the display. · Pressing the microphone PTT switch at this time will transmit your message as well as record it. Do not press the microphone PTT switch if you do not want to transmit your message. 4 Release the VGS channel number key to end the recording at any time and store it into the selected VGS channel. · If the memory becomes full, recording will stop automatically and store the voice memo to memory. · "WRITING" appears on the display while the recording is being stored to memory. 79 Conversation Recorder To record a 30 second conversation: Enter Menu mode and access Menu 009 (CON.REC) {page 20}. Set the Conversation Recorder to ON (or OFF). · The icon appears on the display when this function is activated. The icon does not appear during playback, in Repeater mode, or in Remote Control mode. 3 Press the PF key programmed as [VGS]. 4 Press [LOW] (4) (1s) to store the conversation in VGS channel 4. 80 Playback Press the PF key programmed as [VGS]. Press the key for the VGS channel number you want to play back: [F] (1), [TONE] (2), [REV] (3), or [LOW] (4). · The recording saved in the channel you selected is played back. · To end playback at any time, press [PF1] (CLR). · To exit, press [VGS] again. · During playback, you can switch to any of recordings 1, 2, or 3 by pressing the appropriate key. · While playing a recording, you can transmit the recording by pressing the [PTT] switch. (Continue holding the [PTT] switch until the entire recording is transmitted.) Playback Repeat You can set messages to be repeatedly played back. Enter Menu mode and access Menu 007 (PLAY.BK) {page 20}. Set the the Playback Repeat function to ON or OFF. Playback Repeat Interval If the Playback Repeat function is activated, you can set a time interval for how often the memo/message is played back. Enter Menu mode and access Menu 008 (P.BK.INT) {page 20}. Set the interval from 0 to 60 seconds. 81 CROSS-BAND/ LOCKED-BAND OPERATION (K TYPE MODELS ONLY) This transceiver is capable of receiving signals on one band and retransmitting signals on the other band. This function repeats signals originating from one band, using the other band. For example, a signal received on band A (VHF) is retransmitted on band B (UHF). Similarly, a signal received on band B (UHF) is retransmitted on band A (VHF). Locked-band Repeater: The transceiver uses the same band to receive or transmit a signal. You can set either the A band (A-TX) or B band (B-TX) as the transmit band. Cross-band Repeater: If receiving a signal on the TX band, the transceiver switches the current RX only band to the TX band. This is useful when joining in a group talk. Participants in a group talk need to set a receive and transmit frequency on different bands so as not to miss any conversation within the group. Enter Menu mode and access Menu 403 (RPT.MOD) {page 20}. Set the Repeater operation mode to CROSS (cross-band), A-TX (A band), or B-TX (B band). 3 Turn the transceiver power OFF. 4 Press [TONE] + Power ON. · The Repeater mode is ON and the and icons blink on the display. · You are unable to perform any transceiver functions while in Repeater mode. · To return to normal operation, turn the transceiver power OFF, then press [TONE] + Power ON. Note: u You cannot activate the Repeater function while in single band operating mode or Weather Channel mode. u Activating the Repeater function switches OFF the Automatic Simplex Checker (ASC). u The Time-Out Timer is locked at 3 minutes. u Resetting the transceiver {page 88} will not cancel the Repeater mode. 82 REPEATER HOLD If necessary, you can set the transceiver to remain in the transmit mode for 500 ms after a signal drops. Enter Menu mode and access Menu 404 (RPT.HLD) {page 20}. Set the Repeater Hold function to ON or OFF. REPEATER ID If necessary, you can set the transceiver to transmit your call sign every 10 minutes. Enter Menu mode and access Menu 406 (ID.TX) {page 20}. Set the ID Trasmit function to OFF, MORSE, or VOICE. · To use VOICE transmission, you must have the VGS-1 option installed. When using the VGS-1 option, the ID Transmit function will use VGS channel 3 as the call sign {page 78}. · When selecting MORSE, the call sign stored in Menu 405 {see below} will be transmitted at 20 wpm (words per minute). n Entering your Repeater ID Enter Menu mode and access Menu 405 (RPT.ID) {page 20}. Enter your call sign {page 24}. 83 PACKET OPERATION Connect this transceiver to your personal computer via a Terminal Node Controller (TNC). You can send messages or commands to far away stations, obtain a variety of information via your local bulletin boards, or enjoy other Packet applications. Reference material for starting Packet operation should be available at any store that handles Amateur Radio equipment. Note: u When the distance between the radio antenna and your personal computer is too close, interference may occur. u Do not share a power source between the transceiver and the TNC. When the distance between the TNC and your personal computer is too close, interference may occur. Data terminal pins: No. Name I/O Function q PKD Input Audio signal for packet transmission w DE — PKD terminal ground e PKS Input `L’ is transmitted and the microphone is muted r PR9 Output 9600(bps) repeat signal t PR1 Output 1200(bps) repeat signal y SQC Output Squelch control signal; Closed: `L’, Open: `H’ E — Common ground DATA BAND Select how data will be transmited and received on your transceiver. Enter Menu mode and access Menu 517 (DAT.BND) {page 20}. Set the data band to A (A band receives and transmits), B (B band receives and transmits), ATX.BRX (A band transmits and B band receives), or ARX.BTX (A band receives and B band transmits). DATA TERmINAl SPEED Select 1200 or 9600 bps for the data transfer rate, depending on your TNC. 1200 bps: The transmit data input (PKD) sensitivity is 40 mVp-p, and the input impedance is 10 k. 9600 bps: The transmit data input (PKD) sensitivity is 2 Vp-p, the input impedance is 10 k, and the TNC has dual speed capability with a 2 Vp-p output. 84 Enter Menu mode and access Menu 518 (DAT.SPD) {page 20}. Set the data speed to 1200 or 9600 bps. PC PORT SPEED You can adjust the speed at which the computer and transceiver exchange information, when the transceiver is connected to your computer. Enter Menu mode and access Menu 519 (PC .SPD) {page 20}. Set the PC port speed to 9600, 19200, 38400, or 57600 bps. SQC OuTPuT SETTINg You can set the condition for which the SQC output terminal becomes active. Enter Menu mode and access Menu 520 (SQC.SRC) {page xx}. Set the SQC output activation method to one of the following: · OFF: SQC output remains inactive. · BUSY: When a signal is received on the data band, the SQC output becomes active. · SQL: While CTCSS/DCS is ON and a matching signal is received, the SQC output becomes active. While CTCSS/DCS is OFF, the SQC output becomes active when a busy signal is received. · TX: While transmitting, the SQC output becomes active. · BUSY.TX: When the conditions of BUSY and TX (above) are met, the SQC output becomes active. · SQL.TX: When the conditions of SQL and TX (above) are met, the SQC output becomes active. 85 WIRELESS OPERATION (K TYPE MODELS ONLY) If you also have a compatible Kenwood handy transceiver, you may use it as a remote control for this mobile transceiver. You will control one band on the mobile while sending DTMF tones to the other band from the handheld. This function is useful, for example, when you want to control the mobile from a location outside your vehicle. Note: u As a remote control, you can also use a handy transceiver which does not have a remote control function but a DTMF function. However, you must manually send DTMF tones for control code strings. Skip steps 1 and 3 in "PREPARATION". u The FCC rules permit you to send control codes only on the 440 MHz band. PREPARATION Let us assume band A (VHF) of the mobile transceiver will be controlled. On the handy transceiver: 1 Program a 3-digit secret number. · For the programming method, see the instruction manual for the handheld. 2 Select the transmit frequency on the UHF band. 3 Make the handheld enter Remote Control mode. · For the method, see the instruction manual for the handheld. If not described, consult your dealer. On the mobile transceiver: 4 Enter Menu mode and access Menu 522 (REM.ID) {page 20}. 5 Set the ID code to the same secret number you set on the handy transceiver. 6 Select the receive frequency on band B (UHF). · Match this frequency with the transmit frequency on the handheld. 7 Select band A (VHF) as the TX band or Control band. 8 To cause the mobile to send a control acknowledgment to the handheld, enter Menu 523 (ANS.BK) and set it to ON. · DTMF tones which represent the secret number will be used as an acknowledgment. 9 Turn the transceiver power OFF. 86 10 Press [REV] + Power ON to enter Remote Control mode. · The and icons appear on the display. · To exit Remote Control operation, turn the transceiver power OFF, then press [REV] + Power ON again. CONTROL OPERATION While in Remote Control mode, the DTMF keys of the handheld will function as shown in the table below. Each time you press the desired key, the handheld will automatically enter transmit mode and send the corresponding command to the mobile. Operation DTMF Command Access your mobile via the remote unit (where *** is your 3-digit secret number) A *** # End access of your mobile via the remote unit A # DCS ON 1 Tone ON 2 CTCSS ON 3 DCS OFF (all signalling OFF) 4 Tone OFF (all signalling OFF) 5 CTCSS OFF (all signalling OFF) 6 Call mode ON 7 VFO mode ON 8 Memory mode ON 9 Transmit power (press to toggle between High, Medium, and Low) 0 Frequency (in VFO mode) or Memory channel (in Memory mode) directy entry A XXXXXXX DCS code (when DCS is ON), Tone frequency (when Tone is ON), or CTCSS frequency (when CTCSS is ON) setup B XXX Repeater (Cross-band or Locked-band) ON C Repeater OFF D Step the frequency or Memory channel down Step the frequency or Memory channel up # 87 TRANSCEIVER RESET There are 4 types of transceiver reset available: VFO Reset Use to initialize the VFO and accompanying settings. PART (Partial) Reset Use to initialize all settings other than the Memory channels, the DTMF memory, and the PM channels. PM Reset Use to reset only the Programmable Memory channels to their default values. FULL Reset Use to initialize all transceiver settings that you have customized. There are 2 ways to perform a reset on the transceiver: by key operation and by accessing Menu mode. Key Operation: Turn the transceiver power OFF. Press [F] + Power ON. Rotate the Tuning control and select your desired reset type: VFO, PART, PM, or FULL. 4 Press the Tuning control to set the reset type. · Aconfirmationmessageappearsonthedisplay. · Press [TONE] (BACK) to return to the previous display or [F] (ESC) to cancel the reset. 5 Press the Tuning control again to perform the reset. Note: When in Remote Control or Repeater mode, you cannot reset the transceiver using the Key Operation method. 88 Menu Mode: Enter Menu mode and access Menu 999 (RESET) {page 20}. Set the reset type to VFO, PART, PM, or FULL. Press the Tuning control to set the reset type. · Aconfirmationmessageappearsonthedisplay. · Press [TONE] (BACK) to return to the previous display or [F] (ESC) to cancel the reset. 4 Press the Tuning control again to perform the reset. Note: When the Channel Display function or Key Lock function is ON, the transceiver reset cannot be performed. 89 OPTIONS The following options are available for use with this transceiver: · DFK-3D Detachable Front Panel Kit · MC-45 Microphone · MC-59 Microphone with keypad · MCP-2A MCP (web download software) · MJ-88 Microphone Plug Adapter · MJ-89 Modular Plug Microphone Switch · PG-2N DC Cable · PG-20 DC Cable (7m) · PG-3B Noise Filter · PG-5A Data Cable · PG-5G Programming Interface Cable · PG-5H PC Interface Cable Kit · PG-5F Extension Cable Kit · PS-33 DC Power Supply · PS-53 DC Power Supply · SP-50B External Speaker · VGS-1 Voice Guide & Storage Unit Note: Optional accessories for use with this transceiver may change, post-production. (New options may become available and/or current options may be discontinued.) Please refer to the options catalog(s) for applicable transceivers. 90 ConneCting the Pg-5g/ Pg-5h interfaCe Cables The PG-5G package comes with cable w (below). The PG-5H packages comes with cables q and w (below). q Data communications cable w Serial communications cable To external TNC or other equipment To PC 9-pin D-SUB terminal installing the DfK-3D Panel Kit n installing the sub-Panel Data communications cable pin configuration Serial communications cable pin configuration (pink) (green) 1 Detach the front operation panel from the base unit, then remove the modular cable from both sides. 2 Connect the 4-pin connector of the supplied modular cable to the operation panel. · Align the cable with the cable guide. cable guide 91 3 Connect the supplied sub-panel to the operation panel. · Install the sub-panel in a manner so as not to disrupt the cable. 4 Connect the 8-pin connector of the supplied modular cable to the base unit. · The line filter is pre-installed onto the cable. n installing the Panel bracket 1 Clean and dry the installation location. Do not install the bracket close to an air bag. 2 Remove the release paper from the base of the panel bracket, then secure it in place using the 3 supplied self-tapping screws. · Allow the panel to set for a while, to ensure it remains fast. Otherwise, vibrations may occur. · After removing the release paper, it cannot be reused. 3 Attach the panel holder to the base bracket using the 2 supplied SEMS screws. 4 Attach the operation panel to the panel holder so that it locks in place. sub-panel Approx. 3 cm line filter panel bracket Release paper self-tapping screw flat washer panel holder SEMS screw 92 CONNeCTINg The Pg-5f exTeNSION Cable If necessary, the PG-5F extension cable kit can be used with the DFK-3D panel kit. Using two PG-5F kits, you can extend the cables to the maximum length. (Components marked with an asterisk * are included in the PG-5F kit.) n Connecting Using a Single extension Kit n Connecting Using Two extension Kits microphone external speakers operation panel speaker cables (4 m) * DC power cables (6 m) * extension connector * extension connector base unit * modular cable (4 m) * modular cable (4 m) * line filter * line filter microphone external speakers operation panel speaker cables (4 m) * DC power cables (6 m) base unit modular cable (4 m) & extension connector (2 sets) modular cable (4 m) & extension connector (2 sets) n Installing the line filter Install the line filter approximately 3 cm from the connector which attaches to the base unit. n affixing the Microphone Cable Lock the microphone cable down as shown in the illustration. Approx. 3 cm self-tapping screw flat washer microphone cable cable holder cushion 93 InstallIng the Vgs-1 VoIce guIde unIt Follow the instructions below to install the VGS-1 unit. cushion connector 1 Remove the 8 screws from the cover of the base unit, then remove the cover itself from the unit. 2 From the 5 black cushions supplied with the VGS-1, select the thickest rectangular cushion (20 x 30 x 12 mm) and attach it to the top surface of the VGS-1 unit. · To prevent interferece to the terminal of the VGS-1, ensure that you attach the thick square cushion to the baseplate surface. 3 From the remaining cushions, select the thickest square cushion (21 x 21 x 2.5 mm) and attach it to the printed circuit board. · The remaining cushions are not used with this transceiver. · Ensure that the cushion is placed within the guidelines on the PCB. 4 Insert the VGS-1 unit into the connector on the transceiver. · Press down on the top of the VGS-1 unit to ensure that it is securely attached to the connector. 5 Replace the cover on the base unit and secure it using the 8 screws. VGS-1 cushion guidelines 94 MAINTENANCE GENERAL INFORMATION This product has been factory aligned and tested to specification before shipment. Attempting service or alignment without factory authorization can void the product warranty. SERVICE When returning this product to your dealer or service center for repair, pack it in its original box and packing material. Include a full description of the problem(s) experienced. Include your telephone number along with your name and address in case the service technician needs to contact you; if available, also include your fax number and e-mail address. Don’t return accessory items unless you feel they are directly related to the service problem. You may return this product for service to the authorized Kenwood dealer from whom you purchased it, or any authorized Kenwood service center. Please do not send subassemblies or printed circuit boards; send the complete product. A copy of the service report will be returned with the product. SERVICE NOTE If you desire to correspond on a technical or operational problem, please make your note legible, short, complete, and to the point. Help us help you by providing the following: · Model and serial number of equipment · Question or problem you are having · Other equipment in your station pertaining to the problem Do not pack the equipment in crushed newspapers for shipment! Extensive damage may result during rough handling or shipping. Note: u Record the date of purchase, serial number and dealer from whom this product was purchased. u For your own information, retain a written record of any maintenance performed on this product. u When claiming warranty service, please include a photocopy of the bill of sale or other proof-of-purchase showing the date of sale. CLEANING To clean the case of this product, use a neutral detergent (no strong chemicals) and a damp cloth. 95 TROUBLESHOOTING The problems described in this table are commonly encountered operational malfunctions and are usually not caused by circuit failure. Problem Probable Cause Corrective Action The transceiver will not power up after connecting a 13.8 V DC power supply and pressing [ ]. Nothing appears on the display. 1 The power cable was connected backwards. 2 One or more of the power cable fuses are open. 1 Connect the supplied DC power cable correctly (red to + terminal and black to ­ terminal). 2 Look for the cause of the blown fuse(s). After inspecting and correcting any problems, install a new fuse(s) with the same ratings. The frequency cannot be selected by turning the Tuning control or by pressing microphone [UP]/[DWN]. Memory Recall was selected. Press [VFO]. Most keys and the Tuning control do not function. 1 One of the Lock functions is ON. 2 The transceiver is in Channel Display mode. 1 Unlock all of the Lock functions. 2 With the transceiver power OFF, press [REV] + Power ON to exit Channel Display mode. Memory channels cannot be selected by turning the Tuning control or by pressing microphone [UP]/[DWN]. No data has been stored in any Memory channel. Store data in some Memory channels. You cannot transmit even though you are pressing [PTT]. 1 The microphone plug was not inserted completely into the transceiver. 2 You selected a transmit offset that places the transmit frequency outside the allowable range. 3 The external TNC is transmitting. 1 Switch the power OFF, then insert the microphone plug until the locking tab clicks in place. 2 Turn the offset shift function OFF. 3 Press [PTT] after the TNC has finished transmitting. 96 SPECIFICATIONS Specifications are subject to change without notice due to advancements in technology. General K Type E Type M4 Type Guaranteed range VHF Band A TX & RX 144 ~ 148 MHz 144 ~ 146 MHz UHF Band B TX & RX 438 ~ 450 MHz 430 ~ 440 MHz Frequency range Band A TX 144 ~ 148 MHz — RX 118 ~ 200 MHz — TX (sub UHF) 438 ~ 450 MHz — RX (sub UHF) 300 ~ 470 MHz — RX 200 ~ 300 MHz — Band B TX 438 ~ 450 MHz — RX 300 ~ 524 MHz — TX (sub UHF) 144 ~ 148 MHz — RX (sub UHF) 136 ~ 175 MHz — RX 800 ~ 1300 MHz (excluding cellular band) — Mode F2D/ F3E Antenna impedance 50 Operating temperature range ­20°C ~ +60°C (­4°F ~ +140°F) Power requirement 13.8 V DC ±15% (Negative ground) Frequency stability Within ±5 ppm Current TX VHF Hi Less than 11.5 A Mid Less than 5.0 A Low Less than 4.0 A UHF Hi Less than 10.0 A Mid Less than 6.0 A Low Less than 5.0 A RX Less than 5.0 A Dimensions (W x H x D) Without projections Panel: 140 x 43 x 38.2 mm (5.51" x 1.69" x 1.50") Body: 140 x 43 x 180.7 mm (5.51" x 1.69" x 7.11") With projections Panel: 140 x 43 x 55.4 mm (5.51" x 1.69" x 2.18") Body: 140 x 43 x 213.1 mm (5.51" x 1.69" x 8.39") Weight (approx.) 1.5 kg (3.3 lbs) 97 Transmitter K Type E Type M4 Type RF power output Hi 50 W — Mid Approx. 10 W 25W Low Approx. 5 W Modulation Reactance modulation Maximum frequency deviation Within ±5 kHz Spurious radiation Less than ­60 dB Modulation distortion (300 Hz ~ 3 kHz) Less than 3% Microphone impedance 600 Receiver K Type E Type M4 Type Circuitry Double super heterodyne Intermediate frequency 1st (A band/ B band) 45.05 MHz/ 49.95 MHz 2nd (A band/ B band) 455 kHz/ 450 kHz Sensitivity Less than 0.16 V Squelch sensitivity Less than 0.1 V Selectivity ­6 dB More than 12 kHz ­40 dB Less than 28 kHz Low frequency output (8 ) More than 2 W (at 5% distortion) Note: Receiver specifications apply only when using the main VHF or UHF band. They do not apply to the sub VHF or UHF band. Concerning the received frequency display, an unmodulated signal may be received. This is according to the set intrinsic frequency form. VxU reception (144 MHz + 45.05 MHz) x 2 ­ (430 MHz – 49.95 MHz) = 45.05 MHz, 49.95 MHz (144 MHz + 45.05 MHz) x 4 ­ (430 MHz – 49.95 MHz) x 2 = 45.05 MHz, 49.95 MHz UxV reception (430 MHz – 45.05 MHz) ­ (144 MHz + 49.95 MHz) x 2 = 45.05 MHz, 49.95 MHz (430 MHz – 45.05 MHz) x 2 ­ (144 MHz + 49.95 MHz) x 4 = 45.05 MHz, 49.95 MHz ================================================================================ **Disclaimer:** This guide is volunteer-submitted and provided "as is" without warranty. Use caution and verify all information before proceeding. "I Can Work This Thing" assumes no responsibility for accuracy, safety, or any damage/injury resulting from use. For complex or dangerous procedures, consult qualified professionals. Report issues or suggestions to https://icanworkthisthing.com ================================================================================